Biomedical optics express

Reflection matrix microscopy at 1.6 µm wavelength for label-free deep-tissue imaging.

Jeongwon Youm, Sungsam Kang, Jin Hee Hong, Moonseok Kim, Wonshik Choi

Department of Physics, Korea University, Seoul 02841, Republic of Korea. · Department of Medical Life Sciences, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea.

Key points

From the paper's conclusion
  • Here, we develop, to our knowledge, the first reflection matrix microscope operating at 1.6 μm.

Abstract

Multiple light scattering sets the depth limit of optical microscopy in biological tissue. Reflection matrix microscopy with the multiple-scattering tracing algorithm can overcome this scattering, but its application has so far been limited to wavelengths of 1.3 μm and below. Here, we develop, to our knowledge, the first reflection matrix microscope operating at 1.6 μm. By integrating it with a 1.3 μm channel into a single dual-wavelength system that isolates the wavelength as the principal variable, we quantitatively demonstrate that 1.6 μm markedly outperforms 1.3 μm. The reconstructed phase distortion in the mouse skull is weaker at 1.6 μm and the isoplanatic patch about 1.67 times larger. We resolve osteocytes lying beneath the strongly scattering bone marrow of the skull, a target unreachable at 1.3 μm.