Depth-adapted adaptive optics for three-photon microscopy.
Qi Hu, Jingyu Wang, Huriye Atilgan, Armin Lak, Martin J Booth
Department of Engineering Science, University of Oxford, Oxford, UK. · Department of Physiology, Anatomy, and Genetics, University of Oxford, Oxford, UK.
Key points
From the paper's conclusion- Together, these results established a practical and robust AO-enabled three-photon microscopy strategy that enhanced imaging performance under realistic power constraints.
Abstract
Three-photon (3-P) fluorescence microscopy enables deep in vivo imaging with subcellular resolution, but its performance is fundamentally constrained by the maximum permissible laser power required to avoid tissue heating and photodamage. Under these power-limited conditions, fluorescence signal generation, image contrast, and achievable imaging depth are strongly affected by the illumination beam profile and aberration correction strategy. In this paper, we showed that using a fixed illumination beam size was suboptimal across different imaging depths. We further showed that conventional Zernike-based adaptive optics (AO) correction degrades under reduced Gaussian illumination beam sizes due to loss of modal orthogonality. This degradation results in slow convergence, unintended focal and field-of-view shifts, and excessive wavefront deformations. To overcome these limitations, we introduced a depth-adapted AO framework in which both the illumination beam profile and the aberration correction basis were dynamically matched to the imaging conditions. By combining depth-optimised beam underfilling with a bespoke set of illumination-matched aberration modes, we achieved faster and more stable AO convergence, enhanced fluorescence signal, and image quality during deep in vivo multi-channel neuroimaging. Together, these results established a practical and robust AO-enabled three-photon microscopy strategy that enhanced imaging performance under realistic power constraints.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Seeing deeper with dynamic wavefront shaping in optical microscopyPhotoniques · 2026
- Adaptive optics correction for Bessel beam propagating through spatially varying biological aberrations.Optics express · 2026
- Parallel multi-region adaptive optics module for high-resolution imaging in deep brain microendoscopy.Optics express · 2026
- Iterative aberration compensation of femtosecond 3D-printed microlenses using wavefront measurements.Optics express · 2026
- Photoacoustic-guided reflection-mode wavefront shaping through dynamic biological tissuearXiv · 2026
- Efficient phase-only wavefront shaping at 250 kHz for multimode fiber endomicroscopyarXiv · 2026