Journal of orthopaedic case reports

Diagnostic Accuracy of an 18.5 mm² Magnetic Resonance Imaging Cross-Sectional Area Threshold for Predicting Graft Adequacy (≥8.0 mm) in Quadrupled Hamstring Anterior Cruciate Ligament Reconstruction.

Thomas Mathew, Ashish Mathew, Salman Faris, Francis Johnson, Athul Krishna

Department of Orthopaedics and Traumatology, Pushpagiri Institute of Medical Sciences and Research Centre, Tiruvalla, Kerala, India.

Observational · n=13

Key points

From the paper's conclusion
  • Pre-operative ST CSA below 18.5 mm² was associated with an intraoperative graft diameter <8.0 mm in all 11 patients below the threshold, although 2 of 13 undersized grafts were missed. This threshold may serve as a useful pre-operative screening metric to anticipate the need for graft augmentation, pending external validation.

Abstract

INTRODUCTION: A quadrupled semitendinosus (ST) graft diameter below 8.0 mm is associated with higher failure and revision rates after anterior cruciate ligament (ACL) reconstruction. Pre-operative identification of patients at risk of an undersized graft may facilitate planning for gracilis augmentation or alternative graft selection. OBJECTIVE: To determine the diagnostic accuracy of a pre-operative Magnetic resonance imaging (MRI)-measured ST cross-sectional area (CSA) threshold of 18.5 mm² for predicting an intraoperative quadrupled graft diameter of at least 8.0 mm. MATERIALS AND METHODS: Thirty-seven consecutive patients undergoing arthroscopic ACL reconstruction with a quadrupled ST autograft were enrolled in a prospective observational study. Pre-operative ST CSA was measured on axial MRI at the joint line by a single musculoskeletal radiologist blinded to intraoperative findings. Quadrupled ST graft diameter was measured intraoperatively with a standard graft-sizing block before any gracilis augmentation. A CSA cut-off of 18.5 mm², derived by receiver operating characteristic (ROC) analysis within this cohort, was evaluated against the 8.0 mm adequacy threshold using standard 2×2 diagnostic accuracy statistics. RESULTS: Pre-operative CSA was strongly correlated with graft diameter (Spearman's ρ = 0.948, P < 0.001). At the 18.5 mm² cut-off (adequate graft as the target condition), sensitivity was 100% (95% confidence interval [CI] 85.75-100%), specificity 84.62% (95% CI 54.55-98.08%), positive predictive value 92.31% (95% CI 77.03-97.72%), negative predictive value 100% (95% CI 71.51-100%), and overall accuracy 94.59% (95% CI 81.81-99.34%), with an area under the ROC curve of 0.986 (95% CI 0.957-1.000). All 11 patients with a pre-operative CSA below 18.5 mm² had an inadequate graft (<8.0 mm); two of the 13 patients with an inadequate graft had CSA ≥18.5 mm² (sensitivity 84.62% for detecting an inadequate graft). CONCLUSION: Pre-operative ST CSA below 18.5 mm² was associated with an intraoperative graft diameter <8.0 mm in all 11 patients below the threshold, although 2 of 13 undersized grafts were missed. This threshold may serve as a useful pre-operative screening metric to anticipate the need for graft augmentation, pending external validation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers