Journal of wound care

The clinical effects of a fluidised positioner in prevention of intraoperative pressure injury: a prospective randomised controlled study.

Wen Ke, Xing-Lian Gao, Min Fang

Operating Room, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China. · School of Nursing, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China.

Randomised · n=240

Key points

From the paper's conclusion
  • The findings of this study support that use of a fluidised positioner is feasible and effective in prevention of intraoperative PIs with prolonged surgery.

Abstract

OBJECTIVE: The purpose of this study was to evaluate the effectiveness of a fluidised positioner in the prevention of intraoperative pressure injuries (PIs). METHOD: Fluidised positioners were used to support and protect the skin of patients in the test group from pressure while multilayered foam dressings were used for the control group. Postoperative skin condition and trunk pain 24 hours postoperatively were observed and compared between the two groups. RESULTS: The experimental cohort comprised 240 patients (120 in the test group and 120 in the control group). Postoperatively, five (4.17%) cases of blanchable erythema were observed in the test group while 12 (10.00%) cases were observed in the control group. Patients were further grouped according to the operation duration. When the operation duration was ≥5 hours, the difference in incidences between the two groups was statistically significant (p=0.025). There were 14 (11.67%) cases of trunk pain in the test group and 18 (15.00%) cases in the control group 24 hours postoperatively. There was no significant difference in the incidence of trunk pain between the two groups (p=0.448); however, there was a significant difference in the pain score (p=0.035). Regression analysis showed that the patients who had undergone >4 hours of surgery with a fluidised positioner had less risk of blanchable erythema than those with a multilayered foam dressing after controlling for other factors (odds ratio: 5.874; 95% confidence interval: 1.231, 28.022; p=0.026). CONCLUSION: The findings of this study support that use of a fluidised positioner is feasible and effective in prevention of intraoperative PIs with prolonged surgery.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers