Impact of pH 4.5 cut-off in nasogastric feeding tube confirmation on related X-ray use: single-centre study.
Victoria Williams, Noreena Fitzpatrick, Hardip Malhi, Louise Denner, Jane Fletcher
Nutrition Nurse, Queen Elizabeth Hospital Birmingham, University Hospitals Birmingham NHS Trust. · Quality and Clinical Assurance, Queen Elizabeth Hospital Birmingham, University Hospitals Birmingham NHS Trust.
Key points
From the paper's conclusion- This study describes the impact of a patient safety initiative adopting pH 4.5 or below on the use of chest X-ray at NG tube insertion.
Abstract
Nasogastric (NG) feeding tubes play a vital role in delivering nutrition, hydration and medication to patients who are unable to meet their needs orally. They offer important advantages, one of which is that they can be inserted at the bedside by trained and competent staff, but there are recognised risks including inadvertent placement or displacement into the lungs. National Patient Safety Agency guidance stipulated pH testing to confirm NG tube position and recommended a pH cut-off of 5.5 or below to indicate that the tube is unlikely to be in the lungs and therefore 'safe' to use. There is concern that pH 5.5 is too high and suggestion that a lower pH threshold should be adopted. However, to date this proposal has been widely rejected on the basis that a lower threshold would lead to increased use of X-ray confirmation. This study describes the impact of a patient safety initiative adopting pH 4.5 or below on the use of chest X-ray at NG tube insertion. Snapshot audit data are detailed from 2018 to 2026. Results show that the use of X-rays did not increase with the lowering of the pH threshold. The study demonstrates that using pH 4.5 to improve patient safety is a simple and effective measure, using equipment and techniques that are familiar to nursing staff.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Use of pH Testing to Confirm Feeding Tube Placement: A Quality Improvement ProjectCritical Care Nurse · 2026
- Diagnostic accuracy of gastric aspirate pH measurement for verifying nasogastric tube placement in children receiving home enteral nutrition: An observational diagnostic accuracy study.Nutrition in clinical practice : official publication of the American Society for Parenteral and Enteral Nutrition · 2026
- Application of Combined Gastric Tube Tip Manometry and Auscultation for Nasogastric Tube Positioning in Neurocritical Care Patients With Artificial Airways: A Prospective Diagnostic Pilot StudyNursing in Critical Care · 2026
- Radiological Confirmation of Enteral Feeding Tube Placement Before Initiating Enteral Nutrition: A Review.Cureus · 2026
- Traditional NEX method versus modified length measurement for nasogastric tube placement in adults: a systematic review and meta-analysisEuropean Journal of Medical Research · 2026
- POCUS-guided nasojejunal tube placement reduces malposition and radiation exposure in neonates: a multicenter real-world retrospective study.Pediatric research · 2026