Assessment of thermal behavior for phase transition material through dynamic heating-cooling scenario energy system
Dwi Chandra Adhitya, Dwi Rahmalina, Ismail Ismail, Abid Fahreza Alphanoda, Reza Abdu Rahman
Key points
From the paper's conclusion- Technology energy storage rapidly growth as it plays essential position for the energy transition in modern era, particularly for thermal energy storage (TES).It expands largely considering its flexibility and scalability for different load and application in thermal system.The usage of phase change material (PCM) for TES provides technical benefit since it widely available and cost effective.Howe
Abstract
Technology energy storage rapidly growth as it plays essential position for the energy transition in modern era, particularly for thermal energy storage (TES).It expands largely considering its flexibility and scalability for different load and application in thermal system.The usage of phase change material (PCM) for TES provides technical benefit since it widely available and cost effective.However, specific working indicator for the materials are varied notably, making the development for the PCM and its intended application become complex to assure process control of the energy transfer for each configuration.The present work offers working assessment for six type PCM which divided into low-temperature (LT) and high-temperature (HT) groups.The assessment was performed experimentally on the heating cycle at different rate, followed with different loading scenario for discharge the energy.The initial indicator comes from different melting behavior for each PCM, varying between 61-64.8°C with ΔH 148.2-178.5 J/g for 6 J/g.The challenge starts with cooling function (freezing) as each material experience deviation on transition for phase temperature between 4.8-6.5 °C for LT-group with the highest deviation is obtained from HT-group.The maximum heating rate for LT-group varies between 2.18-5.66°C/min while HT-group indicates a lower maximum heating rate between 1.7-3.33°C/min.Dynamic cooling causes significant variation for the LT-group, specifically between slow and rapid cooling with maximum variation of 1.4 °C/min, indicating the PCM for this group sensitive to different discharge mechanism.In contrast, HT-group demonstrate unsubstantial change for the cooling rate which remain below 1 °C/min for all designed discharge operation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Thermal Performance of a New Latent Thermal Energy Storage Based on Macro-Encapsulated Phase Change Material Modules During the Discharging ProcessApplied Sciences · 2026
- A review of phase change materials: Selection, degradation, and materials compatibilityJournal of Energy Storage · 2026
- Phase-change thermal energy storage: Materials, thermophysics and emerging applicationsNational Science Review · 2026
- Assessment of phase change materials for thermal energy storage in battery systems for heavy-duty vehicle applicationsEnergy Conversion and Management · 2025
- Effective Latent Heat Participation in PCM Cementitious Walls: Split-Cycle Calibration, Cross-Study Validation, and Post-Construction Follow-UpBuildings · 2026
- Performance of a thermal energy storage tank based on latent heat with different capsule allocations. Experimental study in a pilot facilityJournal of Energy Storage · 2025