Computed tomography angiography with three-dimensional reconstruction for planning aortic valve replacement via right anterior mini-thoracotomy.
W Li, J Hu, W Gong, T Chen, C Zhang, R Zhang
Department of Cardiovascular Surgery, First Affiliated Hospital of Anhui Medical University, Hefei, China. · Department of General Thoracic Surgery, The First Affiliated Hospital of Anhui Medical University, Hefei, China.
Key points
From the paper's conclusion- Preoperative CTA with 3D reconstruction enables accurate localisation of the right intercostal incision for AVR via right anterior mini-thoracotomy. This technique preserves minimally invasive surgery benefits and does not increase risks of mid/long-term adverse events.
Abstract
INTRODUCTION: This study explored the value of computed tomography angiography (CTA) with three-dimensional (3D) reconstruction in aortic valve replacement (AVR) via right anterior mini-thoracotomy. METHODS: Clinical data were retrospectively collected from 168 patients who underwent AVR at our institution in China between 1 July 2018 and 1 September 2022. After 1:1 propensity score matching, the experimental group (right anterior mini-thoracotomy) and control group (median sternotomy) each comprised 43 patients. Patients in the experimental group underwent preoperative aortic CTA with 3D reconstruction to guide individualised selection of the intercostal incision site. Perioperative and clinical outcomes were compared between groups. RESULTS: The experimental group had significantly lower 24-hour postoperative drainage volume and shorter mechanical ventilation time, intensive care unit stay, and total hospital stay than the control group (all P<0.001). No intraoperative conversion to median sternotomy or postoperative reoperation for bleeding or pericardial tamponade occurred in the experimental group. Postoperatively, five patients (11.6%) developed atelectasis or pulmonary infection, five (11.6%) developed pleural effusion, and five (11.6%) developed subcutaneous emphysema or pneumothorax; none required thoracentesis. Aortic cross-clamping and cardiopulmonary bypass times were approximately 8 minutes longer, respectively, in the experimental group. At 24 months, the incidence of the composite endpoint-including all-cause mortality, cardiocerebrovascular complications, and readmission for massive pleural effusion or coagulation dysfunction-did not differ significantly between groups. CONCLUSION: Preoperative CTA with 3D reconstruction enables accurate localisation of the right intercostal incision for AVR via right anterior mini-thoracotomy. This technique preserves minimally invasive surgery benefits and does not increase risks of mid/long-term adverse events.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Outcomes of Anatomy‐Guided Ministernotomy and Right Anterior Mini‐Thoracotomy for Minimally Invasive Aortic Valve Surgery: A Prospective Single‐Center CohortJournal of Cardiac Surgery · 2026
- Right Anterior Thoracotomy Aortic Valve Replacement: Technique and Early Outcomes in 156 PatientsHearts · 2026
- Rapid-Deployment Versus Sutured Aortic Valve Replacement Through Right Anterior Thoracotomy: A Single-Team Retrospective Comparison of Operative Efficiency in 192 Consecutive Patients.Life (Basel, Switzerland) · 2026
- Perioperative outcomes after aortic valve replacement via right anterior mini-thoracotomy with a rapid-deployment valve: a consecutive single-centre seriesFrontiers in Cardiovascular Medicine · 2026
- Safety and efficacy of transaortic transcatheter aortic valve implantation via right mini-thoracotomy.Interdisciplinary cardiovascular and thoracic surgery · 2026
- Transaxillary direct-view aortic valve replacement with Intuity Elite rapid-deployment valve.Multimedia manual of cardiothoracic surgery : MMCTS · 2026