On-site WBGT at infant height in a childcare facility during peak summer: sun-exposed areas exceed national published values and shaded ground-level environments reach extreme temperatures.
Saimi Yamamoto, Manato Seguchi, Yukihiro Mori, Yoko Iio, Harumi Ejiri, Morihiro Ito
Graduate School of Life and Health Sciences, Chubu University. · Department of Nursing, College of Life and Health Sciences, Chubu University.
Key points
From the paper's conclusion- On-site WBGT measurement at infant height is essential for evidence-based heat stroke prevention in early childhood education settings in Japan.
Abstract
BACKGROUND: In Japan, the Ministry of the Environment publishes estimated wet-bulb globe temperature (WBGT) values from meteorological stations to guide heat stroke prevention. However, whether these values accurately reflect the thermal environment experienced by children at childcare facilities remains unknown. METHODS: We conducted a repeated-measures field study at a public childcare facility in Aichi Prefecture, Japan, during peak summer (July 29-August 8, 2025). WBGT was measured at two heights (0.5 m and 0.1 m) under three conditions: sun-exposed, shaded, and indoor. Measurements were recorded at 5-min intervals from 9:00 to 17:00 for nine days (shaded and indoor: n = 873; sun-exposed: n = 679). On-site values were compared with WBGT data from the nearest station (9.3 km). Kruskal-Wallis tests with Bonferroni correction, Mann-Whitney U tests, and Bland-Altman analysis were applied. Stratified analyses used Ministry of the Environment (MoE) alert levels and four daily time zones corresponding to childcare schedules. RESULTS: Overall, 88.8% of MoE observations were at the severe warning level or higher; no caution-level readings (<25 °C) occurred. WBGT differed significantly among conditions at both heights (0.5 m: χ2 = 1356.2; 0.1 m: χ2 = 1756.9; both p < 0.001), with sun-exposed > shaded > indoor across all time zones. Sun-exposed WBGT exceeded MoE by a mean of +2.7 °C (0.5 m) and +2.6 °C (0.1 m). A significant proportional error was found in all six conditions (all p < 0.001), indicating that the discrepancy between on-site and published WBGT widened as temperature rose. The maximum recorded WBGT was 42.8 °C at the shaded 0.1 m location. Indoor WBGT was approximately 7 °C below the MoE, and a negative proportional error for the indoor 0.1 m location (B = -0.500) indicated that cooling effectiveness increased during hotter periods. During warning-level conditions, sun-exposed and shaded WBGT were not significantly different (adjusted p = 1.000). The afternoon zone (14:00-17:00) showed the greatest inter-condition disparity (χ2 = 1172.2). CONCLUSIONS: On-site WBGT measurement at infant height is essential for evidence-based heat stroke prevention in early childhood education settings in Japan.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Characterizing regional heterogeneity in heat illness risk using wet-bulb globe temperature-based classification: an analysis of heat illness transports in Japan.International journal of biometeorology · 2026
- Quantifying the influence of a permanent shade pavilion structure on WBGT and activity modification.International journal of biometeorology · 2026
- Estimating hourly outdoor WBGT from routine meteorological observations for heat-stress assessment in tropical Singapore.International journal of biometeorology · 2026
- Summer Heat, Physical Activity, and Sedentary Behavior of Children Outdoors and Indoors in an Urban Setting.Journal of urban health : bulletin of the New York Academy of Medicine · 2026
- Environmental associations with heart-rate responses during field-based submaximal fitness testing in female football players: an exploratory multi-centre study.Science & medicine in football · 2026
- Evaluation of WBGT-based exposure limits.Journal of occupational and environmental hygiene · 2026