Single-Incision Plus One Robot-Assisted Abdominoperineal Resection Using the Hugo RAS System Through a Planned Stoma Site: A Novel Reduced-Port Robotic Surgery.
Shotaro Matsuda, Yoshiro Itatani, Masahiro Maeda, Takehito Yamamoto, Ryosuke Okamura, Yu Yoshida, Koya Hida, Kazutaka Obama
Department of Surgery, Graduate School of Medicine, Kyoto University, Kyoto, Japan. · Department of Surgery, Graduate School of Medicine, Kyoto University, Kyoto, Japan. itatani@kuhp.kyoto-u.ac.jp.
Key points
From the paper's conclusion- SIPORS using the Hugo RAS at a planned stoma site was technically feasible and achieved an oncologically acceptable resection in this patient. It may offer improved cosmesis, reduced postoperative pain, fewer wound complications, and a lower risk of trocar-site incisional hernia. Further experience is needed to confirm its reproducibility and clinical benefits.
Abstract
BACKGROUND: Reduced-port surgery has been developed to minimize abdominal wall trauma while maintaining the benefits of minimally invasive surgery. However, reduced-port robotic rectal surgery remains technically challenging due to interference of external arms. The modular design of the Hugo RAS system (Medtronic, Minneapolis, MN, USA) provides greater flexibility in arm positioning to minimize external arm interference without compromising instrument maneuverability1-4. METHODS: In abdominoperineal resection (APR), the incision for a permanent colostomy is inevitable. We report the first case of completely robot-assisted APR performed using the Hugo RAS system through a planned stoma site. Three robotic trocars were inserted through the planned left lower-quadrant stoma site, and one arm through the right lower quadrant. We call this approach SIPORS, Single-Incision Plus One Robot-assisted Surgery. The procedure is presented in the accompanying video. RESULTS: As the first case, a 50-year-old woman with rectal cancer underwent APR after systemic chemotherapy. The console time was 167 min. The procedure was completed without significant robotic arm interference. The postoperative course was uneventful except for transient cystitis. The circumferential and distal resection margins were 3 and 35 mm, respectively. The mesorectal specimen was complete, 25 lymph nodes were harvested, and the pathological stage was pT3N2bM1. CONCLUSIONS: SIPORS using the Hugo RAS at a planned stoma site was technically feasible and achieved an oncologically acceptable resection in this patient. It may offer improved cosmesis, reduced postoperative pain, fewer wound complications, and a lower risk of trocar-site incisional hernia. Further experience is needed to confirm its reproducibility and clinical benefits.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Single-Port Robot-Assisted Radical Cystectomy Using Combined Umbilical and Perineal Access: Initial Clinical Experience With Exploratory Comparison of Multiport Surgery.The international journal of medical robotics + computer assisted surgery : MRCAS · 2026
- Implementation of a single-port robotic platform into your colorectal surgery practice: a SAGES colorectal committee task force review of evolving robotic technology and innovations.Surgical endoscopy · 2026
- Reduced-port robotic partial hepatectomy using a simultaneous colostomy-closure site via a glove-port: a case report.International journal of surgery case reports · 2026
- Single-port robotic transanal minimally invasive surgery using a novel access port: initial prospective consecutive case series from the UKTechniques in Coloproctology · 2026
- Early experience with the SHURUI single port serpentine arm robotic system with an auxiliary port in gastrointestinal surgery: a descriptive case series.Frontiers in surgery · 2026
- Robot-assisted surgery for colorectal cancer using the Hugo™ RAS system: an observational study with the initial 118 cases and a literature review.Surgery today · 2026