Cavity Margins Sample Shaving as Part of Extended Vacuum-Assisted Breast Biopsy: A Potential Approach to Predict Percutaneous Breast Cancer Excision.
Paula Clarke, Eduardo Carvalho Pessoa, Bertha Andrade Coelho, Daniel de Araújo Brito Buttros, Aleida Nazareth Soares, Bruna Torres Silvestre da Silva, Hélio Rubens de Carvalho Nunes, Carla Priscila Kamiya Carvalho Pessoa,
Department of Obstetrics and Gynecology, Botucatu Medical School, Sao Paulo State University-UNESP, Botucatu, Brazil. · UNIFIPMOC University Center, Montes Claros, Brazil.
Key points
From the paper's conclusion- Cavity margins sample shaving is a potential approach to predict small breast cancer excision and should be added to vacuum-assisted excision in prospective trials. For DCIS, EVAB-CMSH should not be standard of care.
Abstract
BACKGROUND: Excision of small breast cancers has been reported by vacuum-assisted biopsy (VAB). Nevertheless, patients are submitted to surgery, because there is no way to predict excision. The purpose of this study was to evaluate extended vacuum-assisted biopsy (EVAB) associated with cavity margins sample shaving (CMSH) to predict breast cancer excision. METHODS: This is a retrospective database analysis of 120 cancers [both invasive breast cancers (IC) and ductal carcinoma in situ (DCIS)] diagnosed by EVAB-CMSH submitted to surgery with histological data from EVAB-CMSH and surgery. The CMSH was evaluated as a diagnostic test for excision compared to surgery as gold standard. Factors associated with residual tumor, gross residual tumor (GRD) (> 3 mm), and false-negative CMSH after EVAB-CMSH were evaluated. RESULTS: A total of 120 cases were analyzed. Media age was 57 (48.5-69); image tumor size (T) was 11 (8.6-15) mm; pathological tumor size (pT) was 6 (4-10) mm; most cases IC+DCIS 53 (44.2%), DCIS 46 (38.3%), and IC 15 (12.5%); 45 (37.5%) were excised by EVAB-CMSH. CMSH sensitivity 70.7%, specificity 66.7%, false-negative rate 18.33%, and accuracy 69.2%. In multivariate analysis, DCIS pT (p = 0.003, odds ratio [OR] 1.46, 95% confidence interval [CI]) was associated with residual tumor; DCIS pT (p = 0.001, OR 1.34, 95% CI) and the CMSH T (p = 0.001, OR 1.67, 95% CI) with GRD; surgical specimen DCIS T (p = 0.015, OR 1.12, 95% CI) with CMSH false negative. CONCLUSIONS: Cavity margins sample shaving is a potential approach to predict small breast cancer excision and should be added to vacuum-assisted excision in prospective trials. For DCIS, EVAB-CMSH should not be standard of care.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Impact of Cavity Shaving on Margin Status and Re-excision Rates in Breast-Conserving Surgery: Experience from a Single Institute.Archives of breast cancer · 2026
- Contrast-enhanced mammography for selecting B3 breast lesions eligible for vacuum-assisted excision: a retrospective single-centre study.La Radiologia medica · 2026
- Ultrasound-guided vacuum-assisted excision: A minimally invasive solution for managing imaging-histological discordant breast lesions after core needle biopsy.European journal of radiology · 2026
- Impact of Breast Density and Other Factors on Mammography Guided Vacuum Assisted Breast Biopsy Microcalcification Retrieval Rates.Journal of medical imaging and radiation oncology · 2026
- Vacuum-Assisted Breast Biopsy and Post-Biopsy Scarring: Implications for Imaging Interpretation.Diagnostics (Basel, Switzerland) · 2026
- Surgical and Oncologic Impact of Cavity Shave Margins in Breast-Conserving Surgery.Annals of surgical oncology · 2026