Operative neurosurgery (Hagerstown, Md.)

A Perfused Placenta-Based Model for Training in Cerebral Cavernous Malformation Microsurgery.

Marco Galeazzi, Elisa Colombo, Schirin Rahiminia, Mina Pasqualini, Lucrezia Di Stefano, Veronica Percuoco, Jennifer Ashley Watson, Christian Haslinger,

Zurich Microsurgery Lab, Department of Neurosurgery, Clinical Neuroscience Center, University Hospital Zurich, Zurich, Switzerland. · Department of Plastic Surgery and Hand Surgery, University Hospital Zurich, Zurich, Switzerland.

Key points

From the paper's conclusion
  • The described placenta-based model represents a feasible and reproducible platform for training microsurgical removal of cerebral cavernous malformation and may serve as a complementary tool in neurosurgical training programs.

Abstract

BACKGROUND AND OBJECTIVES: Declining operative exposure during residency has increased the need for realistic and accessible surgical simulation models for the acquisition of microsurgical skills. Human placenta has previously been used as a biological substrate for vascular microsurgical training. In this study, we present a placenta-based training model integrated with a 3-dimensional-printed craniotomy to reproduce key steps of microsurgical resection of cerebral cavernous malformations. METHODS: Human placental tissue was combined with a 3-dimensional-printed pterional craniotomy to create a microsurgical training platform. A cavernous malformation was simulated using placental subunit fragments and clots, which were encapsulated and embedded within the placental parenchyma. The model was perfused through cannulation of umbilical vessels. The simulation procedure reproduced the main surgical steps: dural opening, vascular dissection, lesion exposure, intracapsular dissection with piecemeal removal and dural closure. The model was tested by 2 experienced neurosurgeons and 2 senior residents, who evaluated the simulator using a 5-point Likert scale questionnaire assessing realism, tissue consistency, instrument handling, training value, and overall usefulness. RESULTS: The model could be assembled in a mean time of 16 minutes at negligible costs and standard instrumentation. Up to 8 simulations could be obtained from a single placenta, increasing the model's cost-effectiveness. Evaluators rated the simulator favorably across all the investigated domains. Experts completed the procedure in a mean time of approximately 16 minutes, whereas residents required approximately 35 minutes. CONCLUSION: The described placenta-based model represents a feasible and reproducible platform for training microsurgical removal of cerebral cavernous malformation and may serve as a complementary tool in neurosurgical training programs.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers