Tozuleristide Fluorescence-Guided Resection of Gliomas: Results of a Phase II Investigator-Initiated Study.
Rachel C Fox, Xuemo Fan, Adam N Mamelak, Daniel Gomez, Chirag Patil, Ray M Chu, Jeremy Rudnick, Jethro Hu,
Department of Neurosurgery, Cedars Sinai Medical Center, Los Angeles, California, USA. · Department of Pathology and Laboratory Medicine, Cedars Sinai Medical Center, Los Angeles, California, USA.
Key points
From the paper's conclusion- Tozuleristide demonstrated tumor-specific fluorescence with high sensitivity and PPV at 24 mg. The high PPV suggests that fluorescence may be useful for confirming tumor presence in enhancing gliomas, but the low negative predictive value seen cannot exclude tumor in the absence of fluorescence, particularly in infiltrative margins. A well-controlled Phase III trial is necessary to determine the efficacy of image-guided resection in improving EOR.
Abstract
BACKGROUND AND OBJECTIVES: This Phase II, investigator-initiated, nonrandomized clinical trial evaluated tozuleristide, a tumor-specific near-infrared fluorescence imaging agent, combined with the Canvas® imaging system (Blaze Bioscience) to enhance intraoperative visualization of glial tumors. METHODS: Subjects with newly diagnosed, suspected, biopsy-proven, or previously resected high- or low-grade central nervous system tumors received 24 mg (contrast-enhancing glioma) or 36 mg (non-contrast-enhancing glioma) of tozuleristide 1 to 24 hours before surgery. Tumors were visualized intraoperatively using the Canvas imaging system. Biopsies were collected to assess tozuleristide sensitivity and specificity by comparing with histopathology assessment. Extent of resection (EOR), calculated from preoperative and postoperative MRI, was compared with historical controls. Fluorescence did not guide resection, and subjects were not selected for maximal EOR. RESULTS: Thirty-nine subjects (33 contrast-enhancing, 6 nonenhancing tumors) underwent all study procedures. Fluorescence was observed in 30/33 contrast-enhancing tumors. Across 191 biopsies, fluorescence showed sensitivity = 0.735, specificity = 0.500, positive predictive value (PPV) = 0.847, negative predictive value = 0.333, and accuracy = 0.685. Residual fluorescence occurred only when total resection was unsafe and showed a nonsignificant negative correlation with EOR (r = -0.318). The mean EOR was 90.09% (24 mg tozuleristide) with 12 subjects achieving gross-total resection; 0/6 nonenhancing tumors fluoresced. Among patients with glioblastoma undergoing repeat resection, exploratory comparison with historical controls showed higher gross-total resection rates in tozuleristide-treated subjects (6/11 vs 2/11, P = .076); however, fluorescence was not incorporated into surgical decision-making, and these results thus cannot be interpreted toward efficacy. CONCLUSION: Tozuleristide demonstrated tumor-specific fluorescence with high sensitivity and PPV at 24 mg. The high PPV suggests that fluorescence may be useful for confirming tumor presence in enhancing gliomas, but the low negative predictive value seen cannot exclude tumor in the absence of fluorescence, particularly in infiltrative margins. A well-controlled Phase III trial is necessary to determine the efficacy of image-guided resection in improving EOR.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Contrast-enhancement-defined resection outcomes with sodium fluorescein and 5-aminolevulinic acid in glioblastoma surgery: a multicenter retrospective cohort of 1389 patients.Journal of neuro-oncology · 2026
- EP07.11 Fluorescence navigation and endoscopic assistance in surgery for brain glioblastomasNeuro-Oncology · 2026
- Real-time quantification during indocyanine green fluorescent-guided surgery in canine soft tissue sarcomas and mast cell tumorsScientific Reports · 2026
- Intraoperative Tumor-Tissue Discrimination and Histology-Defined Glioma Grading Using Combined Fluorescence and Diffuse Reflectance Spectroscopy.Neuro-oncology · 2026
- Comparison of an Anti-αvβ3 Integrin NIR Fluorescent Probe and Indocyanin Green for Precision Resection of Naturally Occurring Sarcomas in Dogs-A Randomized Blinded Case-Controlled Pilot Study.Veterinary and comparative oncology · 2026
- Safety and surgical outcomes of sodium fluorescein-guided pediatric brain tumor surgery: a retrospective before-and-after single-center cohort study.Frontiers in surgery · 2026