Utilization and Estimation of Environmental Impact of End-Tidal Control in a Multisite Academic Health System: A Retrospective Observational Cross-Sectional Study.
Jonathon McBride, Elizabeth S Jewell, Xinyi Zhao, Rebecca Pantis, John W Beard, Nirav Shah, Thomas Klumpner, David G Hovord,
From the Department of Anesthesiology, University of Michigan Medical School, Ann Arbor, Michigan. · GE HealthCare, Chicago, Illinois.
Key points
From the paper's conclusion- ETC was used in approximately half of available cases. Variation in the decision to use was significantly driven by in-room anesthesia clinician, with wide variation within this group. Use of ETC was associated with a 62.3% reduction in median FGF and sevoflurane consumption of 39.3%.
Abstract
BACKGROUND: End-tidal control (ETC) is a technology new to the United States that enables automated titration of anesthetic gases while using low-flow anesthesia. Although previous, smaller clinical trials have demonstrated that ETC use leads to reductions in fresh gas flow (FGF), anesthetic agent consumptions, and carbon dioxide equivalents (CO2 equivalents) per hour of maintenance, there is limited information about large-scale deployment of ETC including detailed case information and real-world impact in a large academic health system. We sought to describe the utilization of ETC and quantify the impact of ETC utilization on FGF, sevoflurane consumption, and CO2 equivalents per hour of maintenance of anesthesia. METHODS: Data were obtained from an electronic health record-derived registry for adult patients receiving general anesthesia between April 1, 2023, and September 30, 2024, on an anesthesia machine with ETC available at University of Michigan Health-Ann Arbor locations. Utilization rates of ETC were calculated. Using multilevel mixed-effects models, we assessed case, in-room clinician, and attending anesthesiologist contributions to utilization of ETC and quantified the impact of ETC on FGF, sevoflurane consumption, and CO2 equivalents. RESULTS: In 12,818 included general anesthetics, ETC was used in 6755 (52.7%). ETC use was associated with greater anesthesia duration (odds ratio [OR], 1.27 per hour; 95% confidence interval [CI], 1.23-1.31), involvement of a resident anesthesiologist (OR, 2.11; 95% CI, 1.56-2.86), and cases performed at an ambulatory surgical center (ASC; OR, 1.65; 95% CI, 1.3-2.09). Factors associated with decreased use of ETC included American Society of Anesthesiologists (ASA) physical status III to V (OR, 0.89; 95% CI, 0.80-0.99). In-room clinician explained 38.5% of the variation in ETC use compared to 3.9% due to attending anesthesiologist. ETC was associated with an adjusted difference in median FGF of -1.14 L/min (95% CI, -1.16 to -1.12), difference in mean FGF of -1.00 L/min (95% CI, -1.02 to -0.98), difference in sevoflurane consumption of -5.23 mL/h (95% CI, -5.34 to -5.10), and a difference in CO2 equivalents of -1.06 kg CO2 equivalents/hour (95% CI, -1.12 to -0.99) during maintenance. CONCLUSIONS: ETC was used in approximately half of available cases. Variation in the decision to use was significantly driven by in-room anesthesia clinician, with wide variation within this group. Use of ETC was associated with a 62.3% reduction in median FGF and sevoflurane consumption of 39.3%.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- System-Level Reduction in Anesthetic Greenhouse Gas Emissions: Central Nitrous Oxide Deactivation, Clinical Decision Support, and Secular Change in a Multicenter Interrupted Time-Series Study.Anesthesia and analgesia · 2026
- "The Dual Benefit of TIVA-TCI: A Real-World Analysis of Economic and Environmental Superiority over Inhaled Anaesthesia".Anaesthesia, critical care & pain medicine · 2026
- Carbon footprint of total intravenous anaesthesia vs. inhalational sevoflurane anaesthesia in adults: a modelling studyAnaesthesia · 2025
- The environmental impact of free-flow versus on-demand gas release for dental inhalation sedation.British dental journal · 2026
- Combining an anaesthetic conserving device with a circle breathing system to minimise isoflurane waste: an in vitro study.Veterinary anaesthesia and analgesia · 2026
- Barriers and facilitators to the use of total intravenous anaesthesia amongst anaesthesiologists: a systematic review using the Theoretical Domains FrameworkBMC Health Services Research · 2026