Anesthesia and analgesia

Anesthetic Technique and Hospital Length of Stay in Modern Transcatheter Aortic Valve Replacement: A Randomized Controlled Trial.

George B Whitener, Loren R Francis, Toby B Steinberg, Stephanie K Whitener, David B Carroll, Bethany J Wolf, Nicolas H Pope, Nicholas S Amoroso,

From the Department of Anesthesia and Perioperative Medicine, Medical University of South Carolina, Charleston, South Carolina. · Department of Public Health Sciences, Medical University of South Carolina, Charleston, South Carolina.

Randomised · n=170

Key points

From the paper's conclusion
  • In a modern TAVR program, anesthetic technique did not influence hospital LOS or other clinical endpoints during the study. These findings suggest that the efficiency differences previously associated with MAC may not persist in current TAVR practice. Anesthetic choice can be individualized without substantially altering hospital throughput in similar practice settings.

Abstract

BACKGROUND: Observational studies have suggested that monitored anesthesia care (MAC) improves hospital throughput in transcatheter aortic valve replacement (TAVR), though these findings largely reflect earlier practice patterns with longer hospitalizations, evolving care pathways, and limitations inherent to retrospective designs. METHODS: We conducted a single-center, prospective randomized controlled trial of 170 patients undergoing elective transfemoral TAVR. Patients were randomized 1:1 to MAC or general endotracheal anesthesia (GETA) with intraoperative transesophageal echocardiography. The primary outcomes were hospital length of stay (LOS), 30-day mortality, and intensive care unit (ICU) admission. The secondary outcome was paravalvular regurgitation (PVR). Other prospectively tracked perioperative efficiency metrics included procedure time and operating room time. RESULTS: There was no significant difference in hospital LOS between the two groups (median difference in LOS, MAC vs GETA: 0.02 days (95% confidence interval [CI], -0.09 to 0.15 days); P = 0.631). There were no 30-day deaths in either group. ICU admission rates (P = 0.634) were similar between arms. No significant differences were observed in PVR rates (P = 0.934), procedure time (P = 0.142), or operating room time (P = 0.439). CONCLUSIONS: In a modern TAVR program, anesthetic technique did not influence hospital LOS or other clinical endpoints during the study. These findings suggest that the efficiency differences previously associated with MAC may not persist in current TAVR practice. Anesthetic choice can be individualized without substantially altering hospital throughput in similar practice settings.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers