Novel use of far UV-C light as a surface disinfectant in the poultry industry: trials on broiler farms show reduced bacterial burden in poultry anterooms and on wellington boots.
Katharina Watson, C Laudham, D Francis, S Daniels, S Green
Department of Agricultural Science and Practice, Royal Agricultural University, Stroud Road, Cirencester, GL7 6JS UK. · UV Care 222, School Street, Pontyclun, CF72 9FF UK.
Key points
From the paper's conclusion- Overall, there was a significant cfu reduction between treatments ( p < 0.001), after wellington boot exposure to far UV-C irradiation compared to pre-exposure cfu counts and cfu’s on control boots.
Abstract
UNLABELLED: Far ultraviolet-C (UV-C) irradiation at 222 nm has widely been shown to deactivate bacteria, viruses and fungi in in-vitro experiments. However, there are few studies testing the technology on real life surface. There are no peer reviewed studies on the efficacy and feasibility of far UV-C disinfection in real-life agricultural settings. The aim of this study was to investigate whether far UV-C irradiation installations on UK broiler poultry farms could reduce bacterial surface burden. On two farms one pair of wellington boots was submitted to far UV-C irradiation at 222 nm after staff exiting the bird housing, using a purpose build disinfection box. Swabs (n = 780) were taken from the bottom side of the soles before and after irradiation and from a pair of non-irradiated control boots. In a separate trial wall mounted Far UV-C systems were installed in a poultry anteroom and vestibule. Swabs (n = 615) were taken from irradiated and non-irradiated (control) anteroom floors divided into 4 zones (L1-4), vestibule floors divided into 2 zones (V1, V2) and walls divided into 2 zones (VW1, VW2) and the door handle (VD) leading to bird housing. For both studies surface swabs were taken twice a week during the first 4-5 weeks of a bird crop. This was repeated over 3-4 and 4-5 crops for the wellington trial and the poultry anteroom trial respectively. Swabs were plated in the laboratory and the number colony forming units (cfu's) were determined. Overall, there was a significant cfu reduction between treatments (p < 0.001), after wellington boot exposure to far UV-C irradiation compared to pre-exposure cfu counts and cfu's on control boots. Despite some technical challenges, across most anteroom and vestibule sampling locations, cfu's from swabs taken from far UV-C irradiated areas were significantly lower than cfu's from control area swabs. Far UV-C irradiation in livestock settings could be a promising added biosecurity layer on broiler farms and could be applicable to a range of livestock systems. Further research and development is required in areas such as installation adaptations to farms systems and settings, feasibility of implementation and cost benefit analyses. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at https://doi.org/10.1186/s44364-026-00048-z.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A prototype far ultraviolet-C light box for disinfection of children's toys.Journal of infection prevention · 2026
- 233 nm far-UV-C radiation for biofilm inactivation.Photochemistry and photobiology · 2026
- Validated computational modeling to evaluate spatial inactivation of airborne pathogens by Far-UVC irradiation.Photochemistry and photobiology · 2026
- UV Inactivation of Bacteria and Viruses on Surfaces: Mechanistic Insights and Testing Method ComparisonsACS ES&T Engineering · 2026
- Effect of 405 nm Violet-Blue Light on the Culturable Bacterial Load of Worn FFP2 Respirators.Pathogens (Basel, Switzerland) · 2026
- Effectiveness of ultraviolet-C robots in isolation room disinfection: Impact of dose, distance, and direct exposure on environmental surface decontamination.PloS one · 2026