From the paper's conclusion
  • The bootstrap bound-hitting frequency is proposed as a practical identifiability diagnostic with provisional 10%/30% screening thresholds, embedded in a tiered engineering workflow and transferable to other empirical strength criteria affected by parameter coupling.

Abstract

Abstract The Hoek–Brown criterion is widely used for rock-mass strength characterization; however, its material constant m i is often calibrated from limited triaxial datasets without formal uncertainty quantification. This study shows that such calibrations can be practically non-identifiable even when residual diagnostics are unremarkable and the optimizer converges consistently. A fifteen-specimen triaxial dataset from a hydrothermally altered igneous rock was analysed using nonlinear calibration, BCa bootstrap resampling (B = 2000), leave-one-out diagnostics, sample-size analysis, a UCS-anchored joint calibration, uncertainty propagation, sensitivity analysis, and variance decomposition. A fifteen-specimen uniaxial vein dataset served as a methodological control, with petrography and X-ray diffraction providing mechanistic interpretation. The triaxial-only calibration yielded m i = 8.25 and σ ci = 90.31 MPa with severe parameter coupling (ρ = − 0.982); leave-one-out removal of single specimens altered m i by up to 890% (CV = 147.7%). Bootstrap analysis showed 48.9% of resampled fits reaching parameter bounds, an interior-only BCa 95% interval for m i of 0.11–36.89, and propagated 95% parameter-uncertainty intervals of 83–106% of the median rock-mass strength at engineering-relevant confinements. Anchoring the calibration with the fifteen uniaxial determinations already in hand, which observe σ ci directly because the criterion reduces to σ 1 = σ ci at σ 3 = 0, eliminated bound-hitting (f = 0%) and shifted m i from 8.25 to 19.25, exposing the trade-off ridge empirically while leaving precision modest (CV ≈ 37%). Petrography and diffraction identified a silicic-to-argillic alteration gradient that provides a plausible independent explanation for the strength dispersion (CV = 37.8%) obscuring the confinement signal; the vein control showed plausible m i assumptions diverging by 36% at σ 3 = 10 MPa in the absence of triaxial data. The bootstrap bound-hitting frequency is proposed as a practical identifiability diagnostic with provisional 10%/30% screening thresholds, embedded in a tiered engineering workflow and transferable to other empirical strength criteria affected by parameter coupling.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers