Journal of Engineering and Applied ScienceOpen accessCalibration

Alzheimer’s diagnosis from EEG with reliable probabilities: subject-wise, leakage-free evaluation and isotonic calibration

Hamed Shamsi

Karadeniz Technical University

Key points

From the paper's conclusion
  • Conclusions The lightweight, interpretable EEG workflow produced reliable, calibrated probabilities under subject-wise, leakage-free evaluation and supported explicit clinical operating points.

Abstract

Abstract Background Electroencephalography (EEG) provides a low-cost, non-invasive view of millisecond-scale brain dynamics; however, its clinical value depends on reliable probabilities and deployment-aware evaluation, rather than accuracy alone. Objective This study aimed to deliver a simple EEG approach for Alzheimer’s Diagnosis (AD) that returns calibrated subject-level probabilities and reports pre-specified clinical operating points, all under subject-wise, leakage-free validation. Methods Resting-state, eyes-closed EEG from OpenNeuro ds004504 was pre-processed (resampled to 128 Hz, 0.5–45 Hz band-pass, 50 Hz notch, average reference), segmented into 8-s epochs with 4-s overlap, and quality-controlled ( $$\ge$$ 20 valid epochs per subject). Wavelet Scattering Transform features were then extracted under two configurations ( $$J=6/7, Q=8$$ ), pooled to lobar regions with mild weights, and aggregated into subject-level statistics. Feature learning used an $$\ell _1$$ -penalized logistic selector followed by an $$\ell _2$$ -regularized logistic classifier, with performance estimated via 5-fold GroupKFold to produce subject-wise out-of-fold (OOF) logits. Base probabilities were calibrated using isotonic regression, combined through linear ensembling, and then recalibrated. We summarized discrimination (AUC, PR-AUC), calibration (Brier score, ECE), threshold behavior, and clinically oriented operating points (Sens@Spec, Spec@Sens); uncertainty was quantified using bootstrap confidence intervals derived from OOF predictions. Results After quality control, 59 subjects (31 AD/28 HC; 6,957 epochs) remained. The calibrated ensemble achieved an AUC of 0.930 and a PR-AUC of 0.931; the Brier score improved from 0.107 to 0.102, and the ECE decreased from 0.051 to $$\sim 0.000$$ . Bootstrap resampling ( $$N=1000$$ ) yielded mean AUC $$=0.932$$ (95% CI $$[0.864,\,0.980]$$ ). Thresholds $$t=0.380$$ (F1-optimal) and $$t=0.5$$ produced identical $$F_1=0.839$$ and accuracy $$=0.831$$ . Clinically, $$t=0.375$$ prioritized sensitivity (0.935), whereas $$t=0.667$$ prioritized specificity (1.00; no false positives). Conclusions The lightweight, interpretable EEG workflow produced reliable, calibrated probabilities under subject-wise, leakage-free evaluation and supported explicit clinical operating points. While external, multi-center validation remains necessary, these findings support probability-aware EEG decision support for AD.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Alzheimer’s diagnosis from EEG with reliable probabilities: subject-wise, leakage-free evaluation and isotonic calibration — Science Skim