Long-term dynamic monitoring of a masonry tower: a case study of Arnolfo Tower within Palazzo Vecchio in Florence, Italy
Marco Tanganelli, Riccardo Mario Azzara, Francesco Trovatelli, Stefania Viti
Key points
From the paper's conclusion- This article presents the results of an extensive two-year dynamic and thermal-hygrometric monitoring campaign carried out on the Arnolfo tower within the Palazzo Vecchio, one of the most significant historical buildings in Florence.
Abstract
Dynamic monitoring and identification are widely used in structural engineering for assessing the seismic behaviour of buildings. These techniques are particularly suitable for monumental masonry buildings, which have remarkable complexity, both in the geometry and material heterogeneity, and cannot be investigated through destructive surveys. However, monitoring data can be influenced by accidental occurrences and atmospheric agents. Because temperature and humidity variations affect the dynamic behaviour of buildings, long-term monitoring is required to achieve a reliable assessment of modal frequencies and consequently mechanical properties. This article presents the results of an extensive two-year dynamic and thermal-hygrometric monitoring campaign carried out on the Arnolfo tower within the Palazzo Vecchio, one of the most significant historical buildings in Florence. This monitoring provided a substantial dataset of the two main modal frequencies of the tower, which was compared to the ambient conditions observed during monitoring. Numerical simulations, carried out considering the experimental frequency variability range, allowed us to evaluate the effect of the frequency variation on the Young's modulus hypothesised for the building.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Applicability of Site-Level Operational and Environmental Information for Long-Term Heritage Timber Monitoring: Vibration Response and Tilt-Monitoring Baselines at Xuankong TempleBuildings · 2026
- Residual-informed deep meta regressor for predicting modal frequencies of historical masonry buildings under environmental and operational data scarcityMechanical Systems and Signal Processing · 2025
- A Seismic Assessment Approach for Historical Masonry AggregatesHeritage · 2026
- A multi-technique approach to long-term structural health monitoring of the Garisenda Tower (Italy)Structural Health Monitoring · 2026
- Damping ratio identification of a volumetric modular high-rise buildingEngineering Structures · 2026
- A Damage-Spectrum Framework for Specifying the Indoor Climate of Historic BuildingsBuildings · 2026