Padlock probe–RCA–Cas12a for cancer liquid biopsy: molecular interface engineering, analytical validation, and clinical translation
Siyu Li, Weixing Zhao, Xingru Ao, Jingjing Zhi, Jun Jiang
Key points
From the paper's conclusion- We outline analytical validation requirements, including detection and quantification limits, specificity, matrix effects, reproducibility, contamination control, and concordance with orthogonal methods.
Abstract
Liquid biopsy enables minimally invasive assessment of tumor-derived biomarkers, but reliable early cancer detection and longitudinal monitoring remain challenging because of low target abundance, background nucleic acids, preanalytical variability, and matrix interference. Coupling padlock-probe ligation, rolling circle amplification (RCA), and CRISPR–Cas12a offers sequence-selective recognition, isothermal amplification, and programmable readout. However, overall assay reliability depends on faithful molecular information transfer across the ligation, RCA, and Cas12a-activation interfaces rather than on the sensitivity of individual modules. This narrative review adopts an interface-centered framework to examine ligation-junction selectivity, RCA-product design, direct and secondary Cas12a-activation strategies, and mechanisms of background generation. We critically assess applications involving circulating tumor DNA mutations, circulating microRNAs, extracellular-vesicle-associated analytes, and cell-free DNA methylation, distinguishing integrated or related experimental implementations from component-level precedents and unvalidated extensions. Existing studies demonstrate analytical feasibility for selected targets, but quantitative reliability, scalable multiplexing, and clinical performance remain insufficiently established. We outline analytical validation requirements, including detection and quantification limits, specificity, matrix effects, reproducibility, contamination control, and concordance with orthogonal methods. Translation will require mechanistically traceable signal generation, robust performance in authentic specimens, prespecified thresholds, and validation in representative intended-use populations. Ultimately, progress should be judged by reproducible end-to-end performance and demonstrated contribution to clinical decisions, not by record-low detection limits in simplified systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- One-pot dual-toehold RCA-Cas12a biosensor driven by a preassembled three-arm toehold-gated DNA template for sequence-selective miRNA liquid biopsy.Biosensors & bioelectronics · 2026
- CRISPR-Cas liquid biopsy for NSCLC: analytical evidence and laboratory translation.Clinica chimica acta; international journal of clinical chemistry · 2026
- One-pot SP-EXPAR-integrated CRISPR/Cas14a assay for highly specific and versatile detection of ctDNA mutations in lung cancer patients.Analytical methods : advancing methods and applications · 2026
- Advancements in CRISPR/Cas Technologies for Sensitive Cancer Detection: Mechanisms, Platforms, and Clinical Translation Roadmap.Diagnostics (Basel, Switzerland) · 2026
- Programming CRISPR Compartmentalization on DNA Origami for Multiplexed Biosensing.Analytical chemistry · 2026
- Intelligent Modular Dual-Readout Architecture Driven by CRISPR/Cas13a-CHA Cascade and Machine Learning for Portable Multiplex MicroRNA Liquid Biopsy in Early Lung Cancer.ACS sensors · 2026