The utility of lung ultrasound score as a predictor for extubation success in ventilated neonates
Eman khamis, Osama A. Elagamy, Abeer Salama, Marwa Eldegwi
Kafrelsheikh University
Key points
From the paper's conclusion- Aim of the work This study aimed to evaluate the accuracy of the lung ultrasound severity score (LUSS) as a predictor of extubation outcome in ventilated newborns.
Abstract
Abstract Background Weaning from mechanical ventilation is a challenging decision, as weaning failure can lead to complications. Because of its non-invasive, convenient, and real-time features, ultrasound has great potential for bedside assessment of critically ill ventilated neonates. Aim of the work This study aimed to evaluate the accuracy of the lung ultrasound severity score (LUSS) as a predictor of extubation outcome in ventilated newborns. As a secondary exploratory objective, we evaluated whether combining LUSS with oxygenation parameters (OI and S/F ratio) provides additional discriminatory value. Study design A prospective observational cohort study was conducted at the NICU of Kafrelsheikh University Hospital. Neonates who were mechanically ventilated for more than 48 h and ready for weaning were included in the study. Lung ultrasound was performed 1 h before planned extubation to assess the predictive value of LUSS for extubation outcome and again 48 h after extubation to assess subsequent changes in lung aeration. The included infants were then categorized into two groups: success group and failure group based on extubation outcome. Results A total of 60 newborns were included, of whom 53 (88.3%) were successfully extubated and 7 (11.7%) failed. The success group had significantly lower pre-extubation LUSS than the failure group. The AUC for pre-extubation LUSS was 0.906 (BCa bootstrap 95% CI: 0.774–0.966; p < 0.001). Among the evaluated thresholds, ≤ 2 yielded the highest Youden index (0.698), with a sensitivity of 69.81% and specificity of 100%. However, a cutoff of ≤ 3 was considered the preferred pragmatic threshold, providing a more balanced sensitivity (81.13%) and specificity (85.71%), with a Youden index of 0.668. In exploratory unvalidated analyses, the combined model including LUSS, OI, and S/F ratio showed an apparent AUC of 0.946; however, this finding should be interpreted cautiously because of the small number of extubation-failure events and absence of internal validation or calibration. Conclusion Pre-extubation LUSS was significantly associated with extubation outcomes in mechanically ventilated neonates. A cutoff of ≤ 3 provided a balanced diagnostic performance in our cohort. However, the additional predictive value of combined models remains uncertain and requires validation in larger studies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Lung ultrasound aeration score as a predictor of extubation failure in neonates: an updated systematic review with meta-analysis and meta-regression.European journal of pediatrics · 2026
- Application of a combined predictive model based on lung ultrasound score trajectory changes in deciding mechanical ventilator weaning for neonatal respiratory distress syndrome: a retrospective studyFrontiers in Medicine · 2026
- Integrated comprehensive assessment for predicting weaning success in difficult-to-wean critically ill patients: the WEAN-US studyCritical Care · 2026
- Combined Lung and Cranial Ultrasound for Early Identification and Severity Stratification of Neonatal Respiratory Distress Syndrome.Journal of visualized experiments : JoVE · 2026
- 43 Predicting home oxygen therapy in preterm infants using lung ultrasound aeration scores: A prospective cohort studyPaediatrics & Child Health · 2026
- Predictive value of pre-extubation lung ultrasound score for respiratory support escalation after delayed extubation in adult cardiac surgery patients.BMC anesthesiology · 2026