CVIR endovascular

Embolisation of simple PAVMs with high-volume detachable non-fibered coils: a 3-year follow-up study.

Daniel A F van den Heuvel, Douwe Sachumsky, Bette Zijp, Johannes J Mager, Marc van Leersum, Marco C Post, Sjors Klompmaker

Department of Interventional Radiology, St. Antonius Hospital, Nieuwegein, The Netherlands. d.van.den.heuvel@antoniusziekenhuis.nl. · Department of Interventional Radiology, St. Antonius Hospital, Nieuwegein, The Netherlands.

Observational · n=50

Key points

From the paper's conclusion
  • HVDNF coils are safe to use for de novo PAVM embolisation, show an excellent technical success rate and are associated with acceptable 6-month and 3-year persistence and coil recanalisation rates.

Abstract

PURPOSE: To determine pulmonary arteriovenous malformation (PAVM) persistence and safety of high-volume detachable non-fibred (HVDNF) coil embolisation of de novo simple PAVMs using computed tomography pulmonary angiography (CTPA) at 6-month and 3-year follow-up. METHODS: This retrospective single-cohort study included patients who underwent embolisation of de novo simple PAVMs, exclusively with HVDNF coils, between January 2018 and January 2021. Primary endpoints were PAVM persistence at 6 months, cumulative persistence at 3 years and coil recanalisation at 6 months and 3 years. Secondary endpoints were technical success, safety, repeat embolisation and vein diameter reduction. Persistence and recanalisation were confirmed with digital subtraction angiography (DSA). RESULTS: This study included 50 patients with 75 de novo PAVMs. PAVM persistence at 6 months was 13.2%; cumulative persistence at 3 years was 17.4%. Coil recanalisation was the persistence mechanism in 10.3% of the cases at 6 months; at 3 years, this was 13.0%. Technical success rate was 98.7%. There were no procedure- or PAVM-related serious adverse events. Repeat embolisation with HVDNF coils was performed in 4 PAVMs after 6 months and 5 PAVMs after 3 years. Mean vein diameter reduction was 38.3% (SD 29.4%) at 6 months and 44.6% (SD 36.5%) at 3 years. CONCLUSIONS: HVDNF coils are safe to use for de novo PAVM embolisation, show an excellent technical success rate and are associated with acceptable 6-month and 3-year persistence and coil recanalisation rates.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Embolisation of simple PAVMs with high-volume detachable non-fibered coils: a 3-year follow-up study — Science Skim