Economical adjacent structure protection during clinoidectomy and C1-C2 fixation using suture packing material-technical note
Sarbjit Singh Chhiber, Aamir Hussain Hela, Sajad Hussain Arif, Mohsin Fayaz Bhat, Zulfiqar Ali
Key points
From the paper's conclusion- Conclusions Suture packing material is a simple, universally accessible, cost-free adjunct for dural protection, especially valuable in high-risk dura and resource-limited settings.
Abstract
Background Iatrogenic dural injury during cranial bone drilling is a recognized neurosurgical complication, particularly in skull base approaches, redo craniotomies, and where the dura is thin, adherent, or anatomically obscured. Consequences include cerebrospinal fluid leaks, prolonged hospitalization, cortical injury, and infection. Despite advances in craniotomes, protective dural flaps, and feedback-controlled drills, the risk is mitigated but not eliminated. Objective To describe a simple, reproducible, economical technique using readily available suture packing material as a soft mechanical barrier protecting the dura during cranial drilling. Methods and material After standard exposure, drilling is paused as the dura is approached. A strip of suture packing material is placed over the exposed dura with a blunt microdissector. Drilling proceeds under direct vision with minimal pressure, repositioning the barrier as needed, with final dural inspection. The technique was applied during clinoidectomy and C1–C2 fixation. Results The technique was used in 17 consecutive cases (5 clinoidectomies, 12 C1–C2 fixations) without any dural injury, cerebrospinal fluid leak, or material failure. Its woven, fibre-free structure minimized entanglement with the burr—the principal limitation of cottonoids—allowing continuous protection during high-speed drilling. It provided a conformable soft buffer without added dissection, operative time, or cost, being present in every operating room. Conclusions Suture packing material is a simple, universally accessible, cost-free adjunct for dural protection, especially valuable in high-risk dura and resource-limited settings. Comparative studies of dural breach rates are warranted.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- An Injectable Low-Swelling and Mechanically Robust Bioadhesive Sealant for Sutureless Watertight Dural Repair.Advanced healthcare materials · 2026
- Endoscopic-assisted strip craniectomy using a diamond drill bit attached to a dural retractor: a technical paperChild s Nervous System · 2026
- Endoscope-Assisted Bilateral Supraorbital Craniotomies for Reconstruction of a Traumatic Cerebrospinal Fluid Leak in a Complex Skull Base Fracture: A Case Report.Journal of neurological surgery reports · 2026
- Clinical Utility of Rigid Reconstruction Using Unsintered Hydroxyapatite/Poly L-Lactide Composite Plates for High-Flow Cerebrospinal Fluid Leak Closure in Extended Endoscopic Trans-sphenoidal Surgery.Operative neurosurgery (Hagerstown, Md.) · 2026
- Go digital! The surgeon's finger as a digital shield for dura in cranial defects in repeat craniofacial surgery.Child's nervous system : ChNS : official journal of the International Society for Pediatric Neurosurgery · 2026
- A Janus dural patch constructed with hyaluronic acid bioadhesive on electrospun fibers for self-tight sealing, antibacterial and anti-tissue adhesion therapy.International journal of biological macromolecules · 2026