Toronto Joint Department Medical Imaging, Women's College Hospital, University Medical Imaging Toronto, University Health Network, Mount Sinai Hospital, University of Toronto, 610 University Ave, Toronto, ON, M5G 2M9, Canada. adam.farag@uhn.ca. · Toronto Joint Department Medical Imaging, Women's College Hospital, University Medical Imaging Toronto, University Health Network, Mount Sinai Hospital, University of Toronto, 610 University Ave, Toronto, ON, M5G 2M9, Canada.
Key points
From the paper's conclusion- This study demonstrates that OFAI‑DDG significantly improves PSMA PET/CT image quality and quantitative accuracy compared with standard static imaging. The improvements were observed for both 68Ga‑PSMA and 18F‑PSMA tracers, indicating tracer‑independent robustness. The OFAI‑DDG simplified the workflow and reduced time used for patient set-up, while enhancing lesion visualization and quantitative reliability without altering lesion detection, supporting its clinical value for metastatic prostate cancer imaging.
Abstract
BACKGROUND: PSMA PET/CT using 18F‑DCFPyL and 68Ga‑labelled tracers is central to prostate cancer staging, but 68Ga‑PSMA may show reduced sensitivity and quantitative accuracy, partly due to respiratory motion and lower spatial resolution. Device-based motion‑correction methods have limitations. Data‑driven gating (DDG) offers a hardware‑free alternative, though its impact on PSMA PET, especially 68Ga‑PSMA has not been systematically evaluated. To evaluate the quantitative and qualitative performance of the DDG motion-correction method in 68Ga-PSMA and 18F-DCFPyL-PSMA PET/CT, focusing on metastatic lymph node, lung, and bone lesions, and to assess its robustness across tracers. METHODS: This retrospective study included patients with biopsy‑proven prostate cancer who underwent 68Ga‑PSMA or 18F‑DCFPyL PSMA PET/CT for primary staging or biochemical recurrence and had metastatic disease. Motion correction was applied using the OncoFreeze AI™ data‑driven gating (OFAI‑DDG) method. Metastatic lesions were segmented semi‑automatically, and SUV metrics, image noise, and contrast‑to‑noise ratio were quantified by anatomical site in both OFAI-DDG and static images. Qualitative image quality was independently scored by two experienced readers. Statistical analyses included non‑parametric tests, Bland-Altman agreement, regression analyses, tracer comparison, and inter‑reader reliability assessment. RESULTS: After exclusions, 23 68Ga‑PSMA and 40 18F‑PSMA patients were analyzed, yielding 133 and 192 metastatic lesions, respectively. OFAI‑DDG reconstruction significantly increased SUVmean and SUVmax compared with static imaging for both tracers across bone, lymph node, and lung lesions (p < 0.0001), with the largest gains in lung lesions. CNR improved for most lesion types, and image noise was significantly reduced. Qualitative analysis showed better image quality, sharpness, and noise with OFAI‑DDG, with high inter‑reader agreement. OFAI‑DDG performance was robust across tracers and largely independent of lesion location. CONCLUSIONS: This study demonstrates that OFAI‑DDG significantly improves PSMA PET/CT image quality and quantitative accuracy compared with standard static imaging. The improvements were observed for both 68Ga‑PSMA and 18F‑PSMA tracers, indicating tracer‑independent robustness. The OFAI‑DDG simplified the workflow and reduced time used for patient set-up, while enhancing lesion visualization and quantitative reliability without altering lesion detection, supporting its clinical value for metastatic prostate cancer imaging.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Ligand-specific binding kinetics and molecular interactions of clinically used PSMA diagnostic radiopharmaceuticals: an integrated in silico and in vitro study.EJNMMI radiopharmacy and chemistry · 2026
- From Imaging Guidance to Dosimetric and Staging Superiority: Impact of 68Ga-PSMA PET/CT and mpMRI on Target Delineation, Organs at Risk Sparing, and Biochemical Response in Prostate Cancer Radiotherapy-A Single-Center Experience.Life (Basel, Switzerland) · 2026
- Prospective Intraindividual Comparison of Ga-68 PSMA and F-18 FDG Dual-Tracer PET/CT Imaging in Evaluation of High-Grade Prostate Cancer.World journal of nuclear medicine · 2026
- Test-Retest Repeatability of Peripheral Ganglion Uptake on 18F-DCFPyL PET/CT: Implications for Interpreting Benign Uptake on PSMA PET.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2026
- ⁶⁸ Ga-PSMA-11 in Staging of Unfavorable Intermediate- and High-Risk Prostate Cancer Reduces Indication for Noncurative Prostatectomy: A Prospective, Multicenter, IAEA StudyJournal of Nuclear Medicine · 2025
- Radiomics for Differentiating Prostate-Specific Membrane Antigen (PSMA)-Positive and PSMA-Negative Lymph Nodes in Prostate Cancer: An Exploratory 68Ga-PSMA PET-CT Study.Cureus · 2026