Residual radiopharmaceutical activity in venous access devices during PET and SPECT imaging: a real-world clinical observational cohort study.
Rasmus Solem, Nourhan Al-Amiri, Ida Skarping
Radiation Physics, Department of Hematology, Oncology and Radiation Physics, Skåne University Hospital, Lund, Sweden. · Department of Clinical Physiology and Nuclear Medicine, Skåne University Hospital, Lund, Sweden.
Key points
From the paper's conclusion- In this real-world cohort, residual radiopharmaceutical activity within preexisting venous access devices was generally low and showed no discernible impact on visual clinical SPECT or PET interpretation. Prospective studies including a broader range of tracers, access devices, and quantitative endpoints are needed to more fully characterize the clinical implications of residual activity.
Abstract
BACKGROUND: In routine practice, radiopharmaceuticals are administered via a newly placed peripheral intravenous catheter (PIVC). However, many patients referred for nuclear medicine imaging already have a semipermanent venous access device in place, such as a central venous catheter, peripherally inserted central catheter, or subcutaneous implantable venous port. Evidence regarding residual radiopharmaceutical activity within preexisting devices-and its potential consequences for SPECT/PET image quality, diagnostic interpretation, and radiation safety-remains limited. This study aimed to quantify device-related residual radiopharmaceutical activity across commonly used access types and to assess any associated clinical impact during image review. RESULTS: In this observational cohort study at Skåne University Hospital, Sweden, 167 patient administrations during SPECT or PET imaging between June 2023 and January 2026 were included (40% aged < 18 years). Residual activity was evaluated using ROI/VOI based quantification at the venous access site on reconstructed or planar images. Measurements were performed in an activity meter using PIVCs that had been removed from patients prior to imaging. In an experimental setting, representative venous access devices were flushed under controlled conditions to determine residual activity fraction. Residual activity was expressed both as absolute activity (MBq) and as the percentage of the administered activity. Across 214 measurements including 13 radiopharmaceuticals, residual activity was generally low: only 3.3% of the measurements (7/214) exceeded 5% of the administered activity. The highest absolute residual activity was 31 MBq ([99mTc]pertechnetate, PIVC), and the highest proportional residual activity was 17.3% ([99mTc]Tc-MAA, Midline). On clinical image review, no instance of device related residual activity was associated with impaired interpretation or reduced diagnostic confidence. CONCLUSIONS: In this real-world cohort, residual radiopharmaceutical activity within preexisting venous access devices was generally low and showed no discernible impact on visual clinical SPECT or PET interpretation. Prospective studies including a broader range of tracers, access devices, and quantitative endpoints are needed to more fully characterize the clinical implications of residual activity.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Real-time Thermographic Vein Visualization and Extravasation Monitoring During Radiopharmaceutical Injection for Bone Scintigraphy.In vivo (Athens, Greece) · 2026
- Assessment of PET drug adverse events in the U.S. since the implementation of 21 CFR part 212.EJNMMI radiopharmacy and chemistry · 2026
- 20 Drilling it down - Determining the root causes of increased peripheral IV infiltrations and extravasations in paediatric inpatients at London Health Sciences Centre - Children's HospitalPaediatrics & Child Health · 2026
- The effectiveness of vascular access specialist teams for peripheral intravenous catheter management: A systematic review and meta-analysis.Journal of hospital medicine · 2026
- Peripheral intravenous waveform analysis - a novel tool to confirm intravascular catheter placement.Journal of clinical monitoring and computing · 2026
- Infectious Complications of Peripheral Intravenous Catheters, Hematogenous Distant Sequelae, and Evidence-Based Prevention: A Systematic Review and Meta-AnalysisComplications · 2026