Characterization of airway mucus using quantitative MRI: an in vitro proof-of-concept study.
Sam Sedaghat, Jin Il Park, Eddie Fu, Misagh Piran, Ahmadreza Ghasemiesfe, Youngkyoo Jung, Hyungseok Jang
Department of Radiology, University Hospital Heidelberg, Heidelberg, Germany. · Department of Radiology, University of California, Davis, Sacramento, CA, USA.
Key points
From the paper's conclusion- UTE-DESS MRI could be feasible for characterizing airway mucus. T2 relaxation time showed a strong inverse correlation with increasing mucus concentration, indicating its sensitivity to mucus content.
Abstract
OBJECTIVES: A characteristic of chronic obstructive pulmonary disease is mucus hypersecretion. In this proof-of-concept study, we aimed to characterize airway mucus using a quantitative ultrashort echo time (UTE) magnetic resonance imaging (MRI) sequence in a controlled in vitro synthetic mucus model to establish a technical foundation for future in vivo studies. MATERIALS AND METHODS: UTE double-echo steady-state (UTE-DESS) was performed to acquire the signal from free induction decay-like signal and spin/stimulated echo-like signal echoes; quantitative MRI parameters (T1, T2, and diffusivity) were estimated. Synthetic mucus phantoms were prepared using mucin (0.20%, 0.50%, and 1.0%) mixed with xanthan gum (0.10%, 0.25%, and 0.50%) to replicate the viscoelastic properties of human laryngeal mucus, and samples were embedded in 1% agar for imaging. RESULTS: The mucus phantoms with varying concentrations of mucin and xanthan exhibited visual differences in color and opacity. Estimated T1 values were 2.23 ± 0.16, 2.37 ± 0.20, and 2.09 ± 0.18 s (mean ± standard deviation) for the three tubes with relative mucus concentrations of 1, 2.5, and 5, respectively. Corresponding T2 values were 806.6 ± 105.6, 687.4 ± 78.0, and 475.0 ± 41.3 ms, while diffusivity values were 2.36 ± 0.14, 2.31 ± 0.18, and 2.33 ± 0.18 µm2/ms for the three tubes. Only the T2 relaxation times showed a significant linear correlation with mucus concentration (r = -0.9998, p = 0.0112). CONCLUSION: UTE-DESS MRI could be feasible for characterizing airway mucus. T2 relaxation time showed a strong inverse correlation with increasing mucus concentration, indicating its sensitivity to mucus content. KEY POINTS: Question Can a novel quantitative ultrashort echo time MRI sequence noninvasively characterize airway mucus properties and overcome conventional lung imaging limitations in muco-obstructive diseases? Findings In this controlled in vitro model, UTE-DESS MRI mapping demonstrated that T2 relaxation times alone showed a strong inverse correlation with increasing mucus concentrations. Relevance statement This exploratory proof-of-concept establishes a technical foundation for radiation-free, noninvasive T2 mapping to monitor and phenotype chronic obstructive pulmonary disease and other mucoobstructive lung diseases in future in vivo studies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A General High-throughput Mucus Microrheology Platform for Quantitative and Scalable Mucus PhenotypingbioRxiv · 2026
- Thixo-viscoelastoplastic rheological characterisation of human mucus using a multimode BMP constitutive equation approachScientific Reports · 2025
- Evaluation of Water-Related T2 Relaxation Behavior in Hot-Melt Extruded Clotrimazole/PVPVA Solid Dispersions Using Time-Domain NMR.Chemical & pharmaceutical bulletin · 2026
- Musculoskeletal MRI Relaxometry Phantom for T1, T2, and T1ρ Measurements.Journal of magnetic resonance imaging : JMRI · 2026
- Spin Relaxation Rates of Collagen-Associated Water Using Molecular Dynamics Simulations.The journal of physical chemistry. B · 2026
- Visualizing Microvascular Remodeling for Precise Staging of Inflammatory Bowel Disease via Ultralow-Dose Magnetic Resonance Enterography.ACS nano · 2026