Automated radiosynthesis and biodistribution of [18F]fluoroflutamide.
Gina Kaup, Jason Anthony Witek, Shelbie Jaylene Cingoranelli, Jenelle Stauff, David Raffel, Allen Frederick Brooks, Peter James Henry Scott, Jay Samuel Wright
Division of Nuclear Medicine, Department of Radiology, University of Michigan Medical School, Ann Arbor, MI, 48109, USA. · Division of Nuclear Medicine, Department of Radiology, University of Michigan Medical School, Ann Arbor, MI, 48109, USA. pjhscott@med.umich.edu.
Key points
From the paper's conclusion- Herein, we report the optimized automated radiosynthesis of [18F]fluoroflutamide with high purity and sufficient yield for preclinical evaluation of AR-targeted imaging in mouse models of prostate cancer. The lack of uptake in androgen receptor-rich tissues and xenografts suggests impaired in vivo target engagement. While α-tertiary fluorination may attenuate CYP1A2-mediated oxidation to the higher-affinity 2-hydroxyflutamide metabolite, the observed signal is also consistent with reduced intrinsic AR affinity and/or altered pharmacokinetics of the fluorinated analog.
Abstract
BACKGROUND: The androgen receptor (AR) is upregulated in multiple cancers, such as salivary gland cancer, glioblastoma, triple-negative breast cancer, and, most commonly, prostate cancer. Imaging expression of the AR using a radiolabeled AR antagonist would enable non-invasive clinical staging and assessment of tumor heterogeneity via positron emission tomography (PET), complementing the findings of a [68Ga]PSMA-11 scan. Previous efforts described the radiolabeling of enzalutamide with fluorine-18 but were limited by low molar activity. In this study, we showcase an efficient, reproducible automated synthesis of [18F]fluoroflutamide via zinc-mediated radiofluorination and assess its biodistribution in preclinical models of prostate cancer. RESULTS: From 1.87 Ci (69.19 GBq) of [18F]fluoride, [18F]fluoroflutamide was isolated with a non-decay-corrected radiochemical yield of 3.46 ± 1.30% (n = 4) and a radiochemical purity of > 99% in an average 79 min from end-of-beam using a bromoamide precursor. The average Am was 1.57 Ci/µmol (or 58.23 GBq/µmol) at the end of synthesis, and the radiochemical purity after 4 h was > 97%, indicating negligible radiolysis. A biodistribution and imaging study was performed using nude athymic mice with 22Rv1 human prostate cancer xenografts. From the results of this study, we observed a 'mass effect' in which carrier-added mice displayed an increased uptake of the tracer across most organs. CONCLUSIONS: Herein, we report the optimized automated radiosynthesis of [18F]fluoroflutamide with high purity and sufficient yield for preclinical evaluation of AR-targeted imaging in mouse models of prostate cancer. The lack of uptake in androgen receptor-rich tissues and xenografts suggests impaired in vivo target engagement. While α-tertiary fluorination may attenuate CYP1A2-mediated oxidation to the higher-affinity 2-hydroxyflutamide metabolite, the observed signal is also consistent with reduced intrinsic AR affinity and/or altered pharmacokinetics of the fluorinated analog.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Automated Radiosynthesis, Preclinical Validation, and First-in-Human PET Evaluation of the SSTR2 Antagonist [18F]AlF-NOTA-Asp2-PEG2-JR11Journal of Medicinal Chemistry · 2026
- Automated radiochemical synthesis of [68Ga]Ga-FAPI-4 employing modular lab standard with fixed-tubing non-cassette methodology: its preliminary clinical feasibility.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- Simple and Efficient Automated Radiosynthesis of 1-[18F]-IPA Using Solid-Phase Extraction Cartridges Purification.Journal of labelled compounds & radiopharmaceuticals · 2026
- Design and Preclinical Evaluation of Two Prostate-Specific Membrane Antigen-Targeting Trifluoroborate Derivatives Suitable for One-Step Radiofluorination.ACS omega · 2026
- Acridine-Based [68Ga]Ga- and [18F]AlF-Labeled PSMA Radiotracers Enabling High-Contrast PET Imaging with Minimized Undesired Retention.Journal of medicinal chemistry · 2026
- Optimized and Automated Production of [18F]FFNP for Progesterone Receptor PET ImagingOrganic Process Research & Development · 2026