International journal of retina and vitreous

A simple eye model for practicing retinal membrane peeling surgery.

Nuttawut Rodanant, Simaporn Setthawong, Thanchanit Sawetratanastien, Supathida Jiamsawad, Nuttara Sapphaso, Chinnapat Montrisuksirikun

Department of Ophthalmology, Faculty of Medicine Siriraj Hospital, Mahidol University, 2 Wanglang Road, Bangkok Noi District, Bangkok, 10700, Thailand. · Department of Ophthalmology, Faculty of Medicine Siriraj Hospital, Mahidol University, 2 Wanglang Road, Bangkok Noi District, Bangkok, 10700, Thailand. c.montrisuksirikun@gmail.com.

Key points

From the paper's conclusion
  • This simple eye model provides an accessible platform for practicing basic membrane-peeling tasks and has potential utility for developing membrane-peeling skills within a simulation setting.

Abstract

BACKGROUND: To develop and evaluate the educational utility of a simple eye model for retinal membrane peeling training. METHODS: A pilot, cross-sectional study included five ophthalmology trainees with prior intraocular surgery experience but no previous membrane peeling experience, and five vitreoretinal experts. A low-cost model was developed using a 60 ml syringe, reused microforceps, light probe, microscope, and vinegar-soaked chicken eggshells to simulate membrane peeling and related vitreoretinal surgical skills. Experts assessed the model's realism using a 4-point scale. Novices completed pre- and post-task evaluation, after completing three prerequisite tasks: BIOM setup, microscopic adjustments, and micro-forceps proficiency. Membrane peeling performance was assessed for flap creation and complete membrane peeling. Pre-training and post-training novice scores were analyzed. RESULTS: Novices showed encouraging trends toward improved task performance. The mean membrane-peeling time decreased from 459.00 ± 299.26 to 238.60 ± 163.92 s (P = 0.063). Improvements were also observed in the flap-creation score (0.00 ± 0.00 vs. 1.40 ± 0.89; P = 0.125), flap-creation time (67.80 ± 14.84 vs. 40.40 ± 47.26 s; P = 0.313), and membrane-peeling score (0.60 ± 0.55 vs. 1.60 ± 0.42; P = 0.125); however, none of these differences reached statistical significance. The model was rated as user-friendly and effective overall (2.60 ± 0.55 out of 3), particularly for BIOM assembly (2.80 ± 0.45 out of 3) and micro-forceps manipulation (2.40 ± 0.55 out of 3). Experts agreed that the model helped build surgical confidence (2.40 ± 0.89 out of 4). Realism was rated highly for BIOM assembly and mask setup (3.60 ± 0.55 and 3.40 ± 0.55 out of 4, respectively), whereas tactile feedback received moderate ratings (2.00 ± 1.22 out of 4); one expert rated it 3, and two rated it 2. CONCLUSIONS: This simple eye model provides an accessible platform for practicing basic membrane-peeling tasks and has potential utility for developing membrane-peeling skills within a simulation setting.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

A simple eye model for practicing retinal membrane peeling surgery — Science Skim