Virtual-patient nonlinear mixed-effects modelling for data-driven optimisation of single-time-point dosimetry: a proof-of-concept study in [177Lu]Lu-PSMA-617 therapy.
Yeni Pertiwi, Indra Budiansah, Jaja Muhamad Jabar, Muchtaridi Muchtaridi, Freddy Haryanto, Idam Arif, Deni Hardiansyah, Gerhard Glatting
Nuclear Physics and Biophysics Research Group, Physics Department, Faculty of Mathematics and Science, Institut Teknologi Bandung, Bandung, Indonesia. · Medical Physics and Biophysics, Physics Department, Faculty of Mathematics and Science Physics, Universitas Indonesia, Depok, Indonesia.
Key points
From the paper's conclusion- The proposed virtual-patient NLMEM framework enables data-driven optimisation of STP imaging by identifying robust time windows that minimise both population-level error and extreme individual deviations in renal TIAC estimation for [¹⁷⁷Lu]Lu-PSMA-617 therapy. The approach appears transferable to STP dosimetry optimisation for other radiopharmaceuticals.
Abstract
BACKGROUND: Robust single-time-point (STP) dosimetry critically depends on selecting an imaging time that yields reliable estimates of the time-integrated activity coefficient (TIAC). This study developed and evaluated a virtual-patient nonlinear mixed-effects modelling (NLMEM) framework to optimise STP imaging schedules for renal TIAC estimation, using [¹⁷⁷Lu]Lu-PSMA-617 therapy as a proof of concept. METHODS: A previously published NLMEM (sum-of-exponentials structure and parameter distributions) describing renal [¹⁷⁷Lu]Lu-PSMA-617 biokinetics in 63 patients served as the generative model [1]. Based on fixed- and random-effects parameters, 500 virtual patients (VPs) were sampled, and reference TIAC values were computed analytically (rTIAC). For each candidate imaging time, renal activity measurements were simulated by applying proportional noise (7.9%). Estimated STP TIAC values (sTIAC) were obtained via leave-one-out cross-validation and compared with rTIAC to quantify population-level error metrics using mean absolute percentage error (MAPE) and root-mean-square error (RMSE). Time-dependent MAPE-time and RMSE-time profiles were modelled using polynomial fits selected by predefined goodness-of-fit criteria to identify time windows with low and stable errors. Individual-level robustness was assessed by quantifying extreme patient-specific relative deviations (RD) using thresholds of 10%, 20%, and 30%. RESULTS: MAPE- and RMSE-versus-time profiles were concordant and showed a pronounced minimum around 50 h post-injection. Among the investigated imaging time points, the lowest observed population-level error metrics occurred at 48 h, whereas polynomial modelling predicted an optimum centred at approximately 50 h (about 33-67 h). An additional VP-NLMEM evaluation at 50 h demonstrated comparable population-level performance and the lowest frequency of |RD| >30%, while the minima for the 10% and 20% thresholds occurred at nearby imaging times. CONCLUSION: The proposed virtual-patient NLMEM framework enables data-driven optimisation of STP imaging by identifying robust time windows that minimise both population-level error and extreme individual deviations in renal TIAC estimation for [¹⁷⁷Lu]Lu-PSMA-617 therapy. The approach appears transferable to STP dosimetry optimisation for other radiopharmaceuticals.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Single-time-point renal TIA estimation, sparse SPECT/CT data, and nonlinear mixed-effects modelling in [177Lu]Lu-PSMA-617 therapy.Zeitschrift fur medizinische Physik · 2026
- Single‐time‐point renal dosimetry for [ 177 Lu]Lu‐PSMA‐617: Incorporating multi‐cycle population data using nonlinear mixed‐effects modelsMedical Physics · 2026
- Single-Time-Point Time-integrated Activity Estimation for Dosimetry in 177Lu-PSMA Therapy: Evaluation of Analytical and Machine Learning Methods.Clinical nuclear medicine · 2026
- Learning-enhanced hybrid planar-SPECT dosimetry for voxel-level Monte Carlo dose estimation in radionuclide therapy.Physics in medicine and biology · 2026
- Hybrid multi-timepoint/single-timepoint imaging for multi-cycle radiopharmaceutical therapy dosimetry: Performance in [177Lu]Lu-DOTATATE PRRT.The EANM journal · 2026
- Pharmacokinetics of Prostate Cancer Lesions on Dual Time-Point PET/CT: A Predictive Factor for Response to PSMA Radioligand Therapy?Nuklearmedizin. Nuclear medicine · 2026