Development and validation of VentPilot: an AI-based recommendation system for mechanical ventilation.
Hong Yeul Lee, Gaon An, Yeonwoo Jeong, Edward J Schenck, Ho Geol Ryu, Brian W Pickering, Vitaly Herasevich, Daniel A Diedrich,
Department of Critical Care Medicine, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea. · Department of Computer Science and Engineering, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul, 08826, Republic of Korea.
Key points
From the paper's conclusion- In multicenter retrospective validation cohorts, fitted Q-evaluation estimated higher returns for VentPilot than for observed clinician behavior under the prespecified reward function, while greater concordance between observed care and VentPilot recommendations was associated with more favorable clinical outcomes. Further clinical evaluation is warranted to establish VentPilot's safety, usability, and clinical impact.
Abstract
BACKGROUND: Mechanical ventilation requires repeated adjustment to changing patient physiology, but consistent individualized management remains challenging. We developed VentPilot, an artificial intelligence-based system for recommending ventilator settings, and evaluated it in multicenter retrospective validation cohorts. METHODS: VentPilot was developed using offline reinforcement learning on high-resolution physiologic and ventilator trajectories from Seoul National University Hospital (SNUH), with a reward combining ventilator-free days and intensivist-derived preference feedback. We evaluated VentPilot in an internal validation cohort from SNUH and an external validation cohort from Mayo Clinic. Fitted Q-evaluation assessed the estimated return of VentPilot relative to observed clinician behavior under the prespecified reward function. In a complementary inverse probability-weighted analysis, clinical outcomes were compared between patients with higher versus lower concordance between observed ventilator settings and VentPilot recommendations. RESULTS: Among 4296 mechanically ventilated adults, 3002 were included in the derivation cohort, 283 in the internal validation cohort, and 1011 in the external validation cohort. Under the prespecified reward function, fitted Q-evaluation estimated higher returns for VentPilot than for observed clinician behavior in both validation cohorts, with differences in overall reward of 1.6 (95% CI 0.8-2.5) and 1.3 (95% CI 0.6-2.0), respectively. In inverse probability-weighted analyses, higher concordance with VentPilot recommendations was associated with more ventilator-free days within 28 days, with mean differences of 5.0 days (95% CI 2.4-7.6) and 3.1 days (95% CI 1.7-4.6), respectively. Higher concordance was also associated with lower 28-day mortality and shorter ICU length of stay. CONCLUSIONS: In multicenter retrospective validation cohorts, fitted Q-evaluation estimated higher returns for VentPilot than for observed clinician behavior under the prespecified reward function, while greater concordance between observed care and VentPilot recommendations was associated with more favorable clinical outcomes. Further clinical evaluation is warranted to establish VentPilot's safety, usability, and clinical impact.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Intelligent Lung Support in the Intensive Care Unit (IntelliLung): study protocol for an international observational, prospective, multicentre study.BMJ open · 2026
- A Machine Learning Pipeline for Scalable Annotation of Patient-Ventilator Dyssynchrony from Bedside Ventilator DatamedRxiv · 2026
- Residents' Ventilator Management Performance in an Online Pediatric Acute Respiratory Distress Syndrome Case Scenario: Secondary Analysis of the Game-Based Education in Residency Study, 2015-2017.Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies · 2026
- Artificial intelligence in mechanical ventilation: a narrative review of clinical applications and research gaps.Journal of thoracic disease · 2026
- A Patient-Anchored, Oxygen Uptake Rate-Informed Gradient-Boosting Virtual Sensor for Arterial Oxygen Saturation Across a Nine-Hour Monitoring Gap.Entropy (Basel, Switzerland) · 2026
- Artificial Intelligence Algorithm to Monitor Inspiratory Muscle Effort and Patient-Ventilator Dyssynchrony During Mechanical VentilationCritical Care Medicine · 2026