Using insertable cardiac monitors to test determinants of heart rate and activity in captive baboons.
Catherine R Andreadis, Ipek G Kulahci, James Ndung'u, Daisy Kigen, Priscilla Kimiti, Kevin Mugambi Kibe, Noelle R Laske, Janet Mwadime,
Department of Biological Sciences, University of Notre Dame, Notre Dame, IN 46556, United States. · Animal Sciences, Welfare and Ethics Directorate, Kenya Institute of Primate Research, Nairobi, Kenya.
Key points
From the paper's conclusion- Our findings support the future use of ICMs to investigate physiological responses in baboons. These devices' safety and validity represent the plausibility of understanding inter-individual and inter-species variation in heart rate and activity in response to variation in the external environment and in individual internal state.
Abstract
BACKGROUND: Insertable cardiac monitors (ICMs) provide fine-grained, continuous data on cardiac activity. These data have great potential to reveal individual physiology, energetics, and stress responses, with implications for animal health, cognition, welfare, and conservation. However, these devices must be tested for safety, accuracy, and biological validity before being deployed in new species. Here we do so for the Reveal LINQ™ ICM (Medtronic, Minneapolis, MN USA) over an 8-month period in 10 adult female baboons (Papio anubis and P. cynocephalus) at the Kenya Institute of Primate Research in Kenya. We also report data on heart rate, physical activity, and body temperature in unrestrained, conscious, captive baboons during their normal activities. Finally, we test how heart rate and activity levels are predicted by baboon species, body mass, time of day, ambient temperature, social dominance rank, and ovarian cycle phase. RESULTS: The baboons had no adverse reactions to the Reveal LINQ™ ICM. Their mean daytime heart rates (HRs) ranged from 89.6 to 128.0 beats per minute (bpm), and their resting HRs ranged from 74.4 to 98.2 bpm. The fastest observed R-wave interval validated by electrocardiogram (ECG) was 230 milliseconds (ms) (260 bpm), and the slowest was 1270 ms (47.4 bpm). In terms of predictors of HR and activity, HR was highly individualized, while activity level was not: baboon identity explained 41% of the variation in HR, but identity only explained 2% of variation in activity levels. HR was positively correlated with physical activity and HR was highest during daylight hours when the baboons were more active. Dominant baboons had higher HRs controlling for activity and were more active than low ranking individuals. In terms of ovarian cycle phase, HR was higher when individuals were in the periovulatory and luteal phases of the ovarian cycle compared to the follicular phase. CONCLUSIONS: Our findings support the future use of ICMs to investigate physiological responses in baboons. These devices' safety and validity represent the plausibility of understanding inter-individual and inter-species variation in heart rate and activity in response to variation in the external environment and in individual internal state.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- From electrocardiography to energetics: methods, constraints, and practical considerations for heart rate biologging in small animals.Journal of comparative physiology. B, Biochemical, systemic, and environmental physiology · 2026
- Mother Japanese house bats show stronger heart rate increases to biological pup calls than to non-family pup callsFrontiers in Ethology · 2026
- Validation of an open-source hardware for cardio-physiological studies in fish: A statistical equivalence study with a widely used research-grade electrophysiological recording system.Biology open · 2026
- Effect of apnea and food reward on the autonomic modulation of heart rate in bottlenose dolphins (Tursiops truncatus) and belugas (Delphinapterus leucas)bioRxiv · 2026
- Agreement between noninvasive blood pressure obtained by an automated oscillometric blood pressure monitor and invasive blood pressure measurements in anesthetized pumas (Puma concolor).Veterinary anaesthesia and analgesia · 2026
- Seismo-Mat: mattress-embedded inertial sensors for unobtrusive monitoring of heart rate, respiratory rate, and bed occupancy during sleep.IEEE transactions on bio-medical engineering · 2026