From the paper's conclusion- Therefore, employing effective stabilization methods is essential to preserve the integrity of the fecal metaproteome from sample collection to laboratory analysis, particularly over long distances or when rapid freezing options are not readily available.
Abstract
BACKGROUND: Fecal samples are widely used as a proxy for studying gut microbiome composition in both human and animal research. Fecal metaproteomics provides valuable insights by tracking changes in the relative abundance of microbial taxa and their protein functions. To ensure reliable results, it is crucial to minimize alterations in the metaproteome occurring from sample collection to protein extraction. Therefore, employing effective stabilization methods is essential to preserve the integrity of the fecal metaproteome from sample collection to laboratory analysis, particularly over long distances or when rapid freezing options are not readily available. In line with these needs, the second edition of the Critical Assessment of MetaProteome Investigation (CAMPI-2) was specifically focused on testing sample stabilization protocols to be applied before metaproteomic analysis. RESULTS: This collaborative multicenter study assessed the ability of five different stabilization methods, based on two commercial devices and three specific reagents (acetone, lithium dodecyl sulfate, and an RNAlater-like buffer), respectively, to stabilize the fecal metaproteome during room-temperature storage (14 days) and shipment to mass spectrometry facilities. The five methods were tested simultaneously by eight different laboratories across Europe, using aliquots from the same fecal sample. After protein extraction and digestion, duplicate aliquots of the resulting peptides were analyzed independently by two mass spectrometry facilities at distinct international locations. Analysis of the mass spectrometric data using two different search engines revealed that the fecal metaproteome profile differed considerably depending on the stabilization method used in terms of richness, alpha and beta diversity, reproducibility, and quantitative distribution of main taxa and functions. Although each method showed unique strengths and weaknesses, a commercial swab-based device stood out for its remarkable reproducibility and ranked highest for most of the metrics measured. CONCLUSIONS: CAMPI-2 allowed a robust evaluation of five different methods for preserving fecal metaproteome samples. The present investigation provides useful data for the design of metaproteomics and multi-omics studies where fecal sampling cannot be immediately followed by long-term storage at - 80 °C. Further optimization of the tested protocols is necessary to improve stabilization efficiency and control bias in the taxonomic and functional profile of the gut microbiome. Video Abstract.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Fecal metaproteomics from FIT samples: a feasibility study.Journal of microbiological methods · 2026
- Stool Processing for Functional Characterization by Activity-Based Protein Profiling of Bacterial Enzymes in Complex Human Gut Microbiome Systems.Journal of visualized experiments : JoVE · 2026
- High reproducibility demonstrated in a direct-to-consumer microbiome testing workflow under real-world conditions using fecal reference materialbioRxiv · 2026
- Evaluation of Parallel Accumulation-Serial Fragmentation methods for metaproteomics using a model microbiome.bioRxiv : the preprint server for biology · 2026
- FastaLake selects compact metaproteomic databases from large sequence reservoirs by de novo peptide lookupbioRxiv · 2026
- Evaluation of the SPEED Sample Preparation Protocol for Metabolomics.Journal of proteome research · 2026