Reliability of rectal temperature and sprint performance during an intermittent running protocol using motorized and non-motorized treadmills in a hot environment
Takuma Yanaoka, RuiQi Wang, Ryosuke Muto, Hiroshi Hasegawa
Key points
From the paper's conclusion- Conclusions This laboratory-based intermittent running protocol provides reproducible measures of peak sprint speed, T re at the end of the protocol, and ΔT re in a hot environment.
Abstract
Background Although sprint performance during intermittent exercise on a non-motorized treadmill has shown good reliability in thermoneutral environments, its test–retest reliability in hot environments has not been established. The reproducibility of rectal temperature (T re ) during such protocols also remains unclear. This study aimed to determine the test–retest reliability of sprint performance and T re during an intermittent running protocol using motorized and non-motorized treadmills in a hot environment. Methods Following familiarization (Fami), 16 physically active males completed a 43-min intermittent running protocol on two occasions (Trials 1 and 2) in a hot environment (30.3 ± 0.6 °C, 41 ± 2% relative humidity). The protocol comprised repetitions of 2-min exercise blocks consisting of a 5-s rest, 30-s walking at 4.5 km · h −1 , 30-s jogging (45% of peak oxygen uptake [ $$\dot{V}$$ V ˙ O 2peak ]), 30-s running (65% of $$\dot{V}$$ V ˙ O 2peak ), 21-s rest, and 4-s maximal sprinting, with a 3-min break at the 20-min mark. All maximal sprints were performed on a non-motorized treadmill. All other activities were performed on a motorized treadmill with a 1% gradient. Results Mean and peak sprint speeds showed acceptable absolute reliability, with coefficients of variation of 1.9% and 1.7%, respectively; their intraclass correlation coefficients were 0.90 and 0.78, indicating good relative reliability for both speeds. Mean sprint speed increased from Fami to Trial 1 and Trial 2, and from Trial 1 to Trial 2 (+ 0.4–0.8 km · h −1 , all p ≤ 0.004). T re at the end of the protocol and the change in T re (ΔT re ) during the protocol met the prespecified criteria for bias (T re : − 0.01 °C; ΔT re : − 0.05 °C) and limits of agreement (T re : ± 0.50 °C; ΔT re : ± 0.36 °C). Conclusions This laboratory-based intermittent running protocol provides reproducible measures of peak sprint speed, T re at the end of the protocol, and ΔT re in a hot environment. The protocol may be useful for evaluating these outcomes during intermittent exercise in a controlled laboratory setting. Additional familiarization with non-motorized treadmill sprinting in thermoneutral conditions should be considered to minimize learning effects while limiting repeated heat exposure.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Thermoregulatory Response During Cross-Country Marathon Mountain Biking Competitions-An Exploratory Multiple-Case Study.Journal of functional morphology and kinesiology · 2026
- Cooling and exercise performance in adult men at ≥30°C: a task-stratified systematic review and three-level meta-analysis.Journal of thermal biology · 2026
- Test-Retest Reliability of Soft Tissue Vibration Variables Across an Outdoor 5-km Run.Journal of applied biomechanics · 2026
- Optimising Pre-race Physical Preparation for Sprint Events at Major Championships Under New Rule Changes and Competition Formats.Sports medicine (Auckland, N.Z.) · 2026
- The effect of physiologically determined intensity on running variability in healthy men.Sports biomechanics · 2026
- Reliability of Sprint Time and Force-Velocity Profiles During Sprint Acceleration in Elite Rugby Union Players: Inter-Trial Reliability of Linear Encoder, GPS, Timing Gates and Video Analysis.Sports (Basel, Switzerland) · 2026