Performance of Axially Compressed Reinforced Concrete Walls with Openings Strengthened Using Glass Fiber and Welded Wire Mesh Reinforced Engineered Cementitious Composites
Ahmed Hamoda, Mizan Ahmed, Aref A. Abadel, Ahmad Saad, Ramy I. Shahin, Abedulgader Baktheer
Kafrelsheikh University · Curtin University
Key points
From the paper's conclusion- Abstract This study explores the structural behavior of axially loaded reinforced concrete (RC) walls with openings strengthened using glass fiber (GF) or welded wire mesh (WWM) reinforced engineered cementitious composites (ECC).
Abstract
Abstract This study explores the structural behavior of axially loaded reinforced concrete (RC) walls with openings strengthened using glass fiber (GF) or welded wire mesh (WWM) reinforced engineered cementitious composites (ECC). Eleven instrumented specimens were constructed, prepared, and tested up to collapse. The primary factors investigated included opening size and shape, wall slenderness ratio, and the type of reinforcement employed for strengthening. Both square and circular openings were introduced, while the sizes were 0.25 and 0.20 of the wall’s width. Two wall heights were designed leading to slenderness ratios of 7.5 and 9.4. Both GF and WWM were employed to reinforce the ECC layer for strengthening the walls around the openings. Finite-element modeling (FEM) was conducted using Abaqus to simulate the load–displacement response, employing validated material models for concrete, reinforcements, and ECC layers. Experimental and numerical results confirmed that walls with ECC strengthening demonstrated significant enhancements in ultimate load capacity and stiffness compared to unstrengthened samples. Among the strengthening techniques, WWM embedded in the ECC layer yielded the highest ultimate load and energy absorption. A parametric study was performed to assess the influence of ECC layer thickness, indicating that increased thickness improved load capacity, with diminishing returns observed beyond 25 mm. The relationship between ECC thickness and ultimate load was represented by a third-degree polynomial equation with high accuracy. This study features the potential of ECC with embedded WWM as an efficient strengthening solution for reinforced concrete walls with openings.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Application of Engineered Cementitious Composites Reinforced with Orthogonal Welded Steel Mesh in Enhancing Axial Performance of Reinforced Concrete Walls: Experimental and Numerical AnalysisBuildings · 2026
- Strengthening strategies for masonry walls using ECC, steel mesh, and galvanized sheet reinforcement for sustainable constructionStructures · 2025
- Value-oriented SHCC-based strengthening of masonry walls with openings: Integration of glass fiber mesh and steel bars for seismic risk mitigation in constructionCase Studies in Construction Materials · 2025
- Enhancing the performance of reinforced concrete structures using engineered cementitious composites: Mechanisms, effectiveness, and design implicationsJournal of Building Engineering · 2026
- Steel-Wire Mesh Reinforcement of Topology-Optimized 3D-Printed ECC Beams: Experimental and Numerical InvestigationBuildings · 2026
- Flexural Capacity Calculation Method for Pre-Damaged RC Beam-Column Joints Strengthened with High-Strength Steel Strand Mesh-Reinforced ECC.Materials (Basel, Switzerland) · 2026