European Journal of Medical Research

Early blood pressure variability and successful extubation in critically ill patients: a prospective observational study

Xinping Gao, Wen Li, Xianhe Zhang, Peipei Dong, Cui Tian, Canzheng Wei

Observational

Key points

From the paper's conclusion
  • Conclusions Greater blood pressure variability during the first 24 h of critical illness was independently associated with a lower likelihood and slower occurrence of successful extubation.

Abstract

Background Successful extubation is influenced by multiple respiratory, cardiovascular, neurological, and systemic factors. Although blood pressure variability (BPV) may provide information beyond absolute blood pressure levels, whether early BPV is associated with subsequent successful extubation remains unclear. This study investigated the association between early mean arterial pressure (MAP) variability and successful extubation in critically ill adults. Methods In this prospective observational cohort study, adult patients requiring invasive mechanical ventilation were consecutively screened in a medical intensive care unit. MAP was continuously monitored at 5-min intervals during the first 24 h after ICU admission. Early BPV was quantified using mean arterial pressure average real variability (MAP ARV), calculated from the absolute differences between consecutive valid MAP measurements. Patients were categorized according to a prespecified MAP ARV cutoff of 3.5 mmHg. The primary outcome was successful extubation, defined as successful extubation followed by freedom from reintubation or reinstitution of invasive mechanical ventilation within 48 h. Kaplan–Meier analysis and multivariable Cox proportional hazards regression were used to evaluate the association between early MAP variability and time to successful extubation. Results Among 268 patients screened, 204 were included in the final analysis. Of these, 155 patients had lower MAP variability (MAP ARV ≤ 3.5 mmHg) and 49 had higher MAP variability (MAP ARV > 3.5 mmHg). Successful extubation occurred in 122 of 155 patients (78.7%) in the lower-variability group compared with 8 of 49 patients (16.3%) in the higher-variability group ( P < 0.001). In multivariable Cox regression analysis, higher MAP ARV was independently associated with a lower hazard of successful extubation. For each 1-mmHg increase in MAP ARV, the adjusted hazard ratio for successful extubation was 0.59 (95% confidence interval, 0.43–0.80; P < 0.001), after adjustment for age, sex, APACHE II score, sepsis, acute kidney injury, vasopressor use, sedative use, and mean MAP during the first 24 h. Patients with higher early MAP variability also showed a different time-to-ICU-discharge profile and higher observed ICU mortality. Conclusions Greater blood pressure variability during the first 24 h of critical illness was independently associated with a lower likelihood and slower occurrence of successful extubation. Early MAP ARV may provide prognostic information beyond mean MAP and could potentially complement established assessments of ventilator liberation. External validation and further studies are needed to determine its incremental predictive value and underlying mechanisms.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers