Effect of arteriovenous pulsed pneumatic therapy on the hemodynamic microenvironment of autologous arteriovenous fistula in hemodialysis patients
Zhong-Hui Li, Jing-Tong Na, Hai-Yang Sun, Lin Liu, Xiu-Qun Cao, Chun-Xin Li, Xin Wang, Zi-Long Zhou,
Key points
From the paper's conclusion- Background This study aimed to evaluate the effect of arteriovenous pulsed pneumatic therapy on the hemodynamic microenvironment of autologous arteriovenous fistula (AVF) in maintenance hemodialysis patients and explore its potential to prevent AVF dysfunction.
Abstract
Background This study aimed to evaluate the effect of arteriovenous pulsed pneumatic therapy on the hemodynamic microenvironment of autologous arteriovenous fistula (AVF) in maintenance hemodialysis patients and explore its potential to prevent AVF dysfunction. Methods A single-center observational before-and-after study enrolled 78 patients with end-to-side radiocephalic AVF and patent distal radial arteries. Under Doppler ultrasound guidance, individualized pulsed pneumatic compression was applied. Hemodynamic parameters in the AVF region were measured before and after 30 min of therapy. Computational fluid dynamics (CFD) was employed to analyze changes of wall shear stress (WSS) in the AVF before and after therapy, with focus on evaluating the effects of this treatment on WSS in the AVF anastomotic region. Results Arteriovenous pulsed pneumatic therapy increased blood flow in the distal radial artery, brachial artery, and cephalic vein. Antegrade flow in the distal radial artery was reversed to retrograde flow in 6 patients (7.7%). CFD results showed that after treatment, WSS at the anastomotic site increased by 46.5% and 30.2% compared with antegrade and retrograde flow before treatment, respectively, while the low WSS area decreased by 18.8% and 15.0%, and the oscillatory shear index remained close to zero. No adverse events were observed during treatment. Conclusion Arteriovenous pulsed pneumatic therapy increased blood flow in the distal radial artery, reversed its flow direction, and improved the hemodynamic microenvironment by increasing WSS at the anastomosis and reducing low WSS regions. These findings provide preliminary insights into its potential role in maintaining AVF function.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Computational and Experimental Evaluation of a Flow-Conditioning Anastomotic Device for Arteriovenous Fistula Maturation.Bioengineering (Basel, Switzerland) · 2026
- Nursing Ultrasound Monitoring of Arteriovenous Fistulas in Haemodialysis: The ECHO‐NURSE StudyJournal of Renal Care · 2026
- Flow-Induced High-frequency Vascular Wall Vibrations: A New Mechanobiological Stimulus for Vascular Remodeling?Annals of biomedical engineering · 2026
- Pedicular Arteriovenous Fistula (PAVF): Intraoperative Hemodynamic Characterization in Fasciocutaneous Free Flaps.Journal of reconstructive microsurgery · 2026
- Beyond Access Flow: The FLASH Multiorgan Framework for Assessing High-Flow Arteriovenous Fistulas in Hemodialysis.Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association · 2026
- AVF creation in mice disrupts blood flow patterns to impact vasoreactivitybioRxiv · 2026