Real-time structuring of the clinical information section for dopamine transporter SPECT reporting with a small language model pipeline: development and external validation.
Thomas Buddenkotte, Ivayla Apostolova, Susanne Klutmann, Rickmer Braren, Philipp T Meyer, Ralph Buchert
Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246, Hamburg, Germany. · Department of Nuclear Medicine, Medical Center - University of Freiburg, Freiburg, Germany.
Key points
From the paper's conclusion- We therefore developed and evaluated a locally deployable small language model (SLM)-based pipeline to structure and standardize the clinical information section for DAT-SPECT reporting.
Abstract
BACKGROUND: Accurate interpretation of dopamine transporter (DAT)-SPECT depends on clinical context, including symptoms, medication, comorbidities, and structural imaging findings. In routine practice, however, this information is often documented as heterogeneous free text, which may hinder consistent consideration of clinically relevant parameters and limit guideline-compliant reporting. We therefore developed and evaluated a locally deployable small language model (SLM)-based pipeline to structure and standardize the clinical information section for DAT-SPECT reporting. Two retrospective datasets were used. The in-house dataset included clinical information sections from 2,990 DAT-SPECT examinations and was split into training (n = 2,700) and internal test data (n = 290). The external validation dataset comprised 595 clinical information sections from a second institution. A structured dictionary (466 entries across 12 categories) was created by two experienced DAT-SPECT readers and used to manually annotate the training and internal test samples. A Qwen3 1.7B model was fine-tuned by supervised learning to reproduce expert annotations. A rule-based postprocessing pipeline converted model outputs into report-ready structured text, including removal of redundant entries, automated suggestion of scan indication, consolidation of symptom lateralization and time course, reminders for missing guideline-relevant elements, and medication interaction checks. Internal test performance was assessed by expert comparison of SLM output with manual annotation. External performance was assessed by counting the manual corrections required in the postprocessed output under strict criteria. RESULTS: In the internal test dataset, the postprocessed SLM output provided the same information as the expert annotation in 196/290 cases (67.6%), including exact matches in 147/290 (50.7%). Interpretation differences due to free-text ambiguity occurred in 13/290 cases (4.5%), and SLM errors in 41/290 cases (14.1%). In 40/290 cases (13.8%), the SLM output was judged superior to the manual annotation. Among the error cases, 36/41 (87.8%) involved only a single erroneous or missing item. In the external dataset, 446/595 postprocessed outputs (75.0%) required no manual correction before inclusion in the report. Among the remaining 149/595 cases (25.0%), correction of only a single item was required in 111 cases (18.7% of all cases). The mean number of corrections was 0.34 items per case, corresponding to 6.0% of all structured items. CONCLUSIONS: A locally deployable SLM combined with rule-based postprocessing can transform free-text clinical information for DAT-SPECT into standardized, report-ready documentation with good practical usability in an external dataset. End-to-end processing times of typically less than one second on the tested hardware support the feasibility of real-time local deployment. Prospective studies are required to determine its effects on clinical workflow and reporting quality.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- On the utility of ChatGPT in conducting a literature review on deep learning for dopamine transporter SPECT with [¹²³I]ioflupaneNuklearmedizin - NuclearMedicine · 2026
- Difficult-to-interpret dopamine transporter SPECT with [123I]ioflupane in the diagnosis of parkinsonismNuklearmedizin - NuclearMedicine · 2026
- Equivocal Dopamine Transporter Imaging: Integrating Visual Assessment, Quantification, and Clinical Follow-Up.Life (Basel, Switzerland) · 2026
- AI-Powered Structuring of Clinical Information in Parkinson's Disease: An Approach Based on Large Language Models.IEEE journal of biomedical and health informatics · 2026
- A Reproducible Decomposed Large Language Model Pipeline for Structured Abstraction of Multimodal Neuroimaging Reports: Development and Independent Validation in 1,669 Emergency Department Encounters for Dizziness and VertigomedRxiv · 2026
- Dopaminergic Radiopharmaceutical Imaging in Parkinsonian Syndromes: From Molecular Targets to Clinical Decision-Making.Pharmaceuticals (Basel, Switzerland) · 2026