Effects of motion and white matter hyperintensities on reference region based ¹⁸F-SynVesT-1 PET quantification in Alzheimer's disease and healthy volunteers.
Charles Carron, Simon Noë, Greet Vanderlinden, Michel Koole, Georg Schramm, Koen Van Laere
Division of Nuclear Medicine, University Hospitals UZ Leuven, Leuven, Belgium. charles.carron@kuleuven.be. · Nuclear Medicine and Molecular Imaging, Imaging and Pathology, Leuven Brain Institute, KU Leuven, Leuven, Belgium.
Key points
From the paper's conclusion- Data-driven motion correction during reconstruction reduced the impact of head movements and attenuation mismatches, improving image contrast and quantitative accuracy. SUVRCER was less sensitive to motion and WMH than SUVRCSO, indicating greater robustness. When motion and WMH effects were controlled, SUVRCSO provided slightly better group differentiation than SUVRCER. These findings suggest that CSO may be preferred for group comparisons in well-controlled datasets, while the cerebellum represents a more robust reference region in the presence of motion or substantial WMH burden. The study was registered on ClinicalTrials.gov (NCT05384353), first posted on 20 May 2022.
Abstract
BACKGROUND: 18F-SynVesT-1 is a PET tracer targeting synaptic vesicle protein 2A, a surrogate marker of synaptic density. Simplified quantification using pseudo-reference regions such as the centrum semiovale (CSO) or whole cerebellum (CER) has previously been validated in healthy volunteers and Alzheimer's disease. This study assessed how motion correction and white-matter hyperintensities (WMH) affect 18F-SynVesT-1 quantification. We reconstructed 18F-SynVesT-1 images for 40 healthy volunteers and 31 patients with Alzheimer's disease 60-90 minutes post-injection with 3 motion handling methods: no motion correction; 5 minute frame-based post-reconstruction coregistration and averaging, and a high-temporal-resolution data-driven motion correction applied during reconstruction. WMH were segmented from T2-FLAIR images and excluded from the CSO to generate lesion-corrected CSO regions. A region-based voxelwise partial volume correction was applied. SUV and SUVRCSO/CER were compared across motion- and lesion-handling methods and the effects on group differentiation were explored. RESULTS: Data-driven motion correction during reconstruction improved visual image sharpness and increased SUV in high-binding cortical regions (median +0.3-1.0%, p≤0.001) while reducing SUV in the low-binding CSO (median -0.5%, p=0.001). Coregistering and averaging of frames only increased contrast when there was severe motion. The cerebellum was one of the least affected regions by motion correction (median SUV +0.4% with PETDDLM, p<0.001). WMH affected CSO SUV only when ≥25% of the region contained lesions and never affected the cerebellar SUV. SUVRCSO yielded better group differentiation than SUVRCER after accounting for motion and WMH. Individual patients' z-scores differed significantly in both directions depending on the use of SUVRCSO or SUVRCER (e.g. mean absolute difference of 1.00± 0.82 in the precuneus). CONCLUSION: Data-driven motion correction during reconstruction reduced the impact of head movements and attenuation mismatches, improving image contrast and quantitative accuracy. SUVRCER was less sensitive to motion and WMH than SUVRCSO, indicating greater robustness. When motion and WMH effects were controlled, SUVRCSO provided slightly better group differentiation than SUVRCER. These findings suggest that CSO may be preferred for group comparisons in well-controlled datasets, while the cerebellum represents a more robust reference region in the presence of motion or substantial WMH burden. The study was registered on ClinicalTrials.gov (NCT05384353), first posted on 20 May 2022.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Quantification of¹⁸ F-SynVesT-1 binding in healthy ageing and head-to-head comparison with¹¹ C-UCB-JJournal of Cerebral Blood Flow & Metabolism · 2026
- Posture-Related Regional Homogeneity Abnormalities in Cerebral Small Vessel Disease: A Multi-Position MRI Study.CNS neuroscience & therapeutics · 2026
- Multimodal PET/MR imaging in Alzheimer's disease: A comparative study of structural, metabolic, synaptic and perfusion measures.European journal of nuclear medicine and molecular imaging · 2026
- Contribution of Myelin Content to the PET-Measured Amyloid Burden.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2026
- Motion-corrected structural realignment and quantitative voxel targeting in magnetic resonance spectroscopy.Imaging neuroscience (Cambridge, Mass.) · 2026
- Longitudinal diffusion tensor imaging identifies coordinated white matter remodeling during cocaine self-administration in mice.bioRxiv : the preprint server for biology · 2026