Insights into Imaging

Novel toilet filtration system for contrast material removal at the source: first outpatient results

Helena M. Dekker, Alex Hol, Mattijs Maris, Gerard Stroomberg, Mathias Prokop

Observational · n=395

Key points

From the paper's conclusion
  • Critical relevance statement The novel toilet-based filtration system enables substantial iodine recovery from excreted ICM in urine, but limited post-ceCT excretion during short waiting times highlights the need for process adaptations to further increase overall excretion and maximise iodine recovery rates.

Abstract

Objectives Iodinated contrast media (ICM) are essential for diagnostic imaging but impose a substantial environmental burden due to their widespread use. This prospective observational study evaluates the efficiency of a novel toilet filtration system (TFS) for recovering ICM after contrast-enhanced CT (ceCT) and explores factors that contribute to successful implementation of the system. Materials and methods This prospective observational study included consecutive outpatients scheduled for ceCT using Iomeprol as ICM. Patients were informed about the TFS, ICM excretion, and environmental implications. They were asked to wait at least 30 min after scanning and to use the TFS for their first post-ceCT urination. The removal efficiency of the TFS was determined by measuring ICM concentrations in influent and effluent streams. The proportion of administered ICM recovered was calculated from the cartridge’s contents. Results Of 395 consecutive patients undergoing ceCT, 277 (70%) consented to participate, and 273 patients (median age 65.5; IQR: 57.2–73.4; 151 men) successfully used the TFS. The median interval between contrast administration and urination was 36 min (IQR: 31–41). Most patients (81%) waited at least 30 min before voiding. Removal efficiency of the TFS exceeded 99.9% for ICM. Limited ICM excretion led to recovery of 2.78 kg out of 18.41 kg administered Iomeprol (15.1%; 1.36 kg iodine). Conclusion While ICM is efficiently removed using a novel TFS (> 99.9%), ICM excretion during the 30-min post-examination waiting period was limited. The approach can recover approximately 71 kg of ICM per year per 10,000 ceCT examinations, a number that could be further improved through efforts to increase ICM excretion. Key Points Question TFS have the potential to reduce the amount of contrast media entering wastewater, but their effectiveness is unclear. Findings TFS achieved excellent contrast removal, and was well accepted by patients, but contrast excretion within the median 36-min waiting period is limited to 15%. Critical relevance statement The novel toilet-based filtration system enables substantial iodine recovery from excreted ICM in urine, but limited post-ceCT excretion during short waiting times highlights the need for process adaptations to further increase overall excretion and maximise iodine recovery rates.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers