Technical challenges in establishing local native T1 reference ranges in cardiac MRI: a critical review.
Maheran Che Ha, Khairil Amir Sayuti, Yusri Mohammed, Mardhiyati Mohd Yunus, Nurisya Mohd Shah, Mohd Mustafa Awang Kechik, Mohammad Johari Ibahim, Muhammad Khalis Abdul Karim
Department of Physics, Faculty of Science, Universiti Putra Malaysia (UPM), Serdang, Malaysia. · Department of Radiology, Hospital Universiti Sains Malaysia, Kubang Kerian, Malaysia.
Key points
From the paper's conclusion- Critical relevance statement This review identifies technical drivers of T1 variability and proposes a standardization framework, enabling clinicians to establish accurate local reference ranges and improve diagnostic comparability across diverse platforms in clinical radiology practice.
Abstract
Establishing local reference ranges for native T1 in healthy myocardium is critical in cardiac magnetic resonance imaging (CMR) for the accurate detection of myocardial fibrosis and other tissue abnormalities. However, native T1 measurements vary widely and are sensitive to technical factors such as the magnetic field strength, static magnetic field (B0) and radiofrequency (B1) homogeneities, differences in MRI scanners across various vendors, imaging protocols, and specific acquisition parameters employed. These variabilities have consequently hindered the direct comparison of T1 values across different studies and centers. This review aims to evaluate the main technical challenges and methodological inconsistencies that impact the establishment of local native T1 reference ranges in CMR, and review proposals for mitigation, harmonization, and standardization strategies designed to enhance comparability across CMR platforms. A comprehensive literature search was conducted focusing on myocardial native T1 mapping using the modified Look-Locker inversion recovery (MOLLI) technique and its variants, as well as on alternative T1 mapping sequences like ShMOLLI, SASHA, SMART1Map, and SAPPHIRE. Reported native T1 values in healthy myocardium were found to be inconsistent across studies, driven by differences in the magnetic field strength, static magnetic field (B0), and radiofrequency (B1) homogeneities, and vendor-specific hardware and software configurations. Standardization of T1 mapping protocols, including standardized imaging parameters and vendor-specific reference adjustment, is therefore necessary to improve the comparability and reliability of myocardial T1 values across CMR centers. In addition, a robust quality assurance (QA) program and effective quality control (QC) measures are pivotal in ensuring the reliability and consistency of the measurements. KEY POINTS: Question How do technical factors and scanner-specific variabilities hinder the establishment of reliable local native T1 reference ranges for accurate myocardial tissue characterization? Findings Standardization of acquisition parameters, vendor-specific benchmarks, and robust quality assurance programs effectively minimize inter-scanner variability, ensuring reliable and comparable native myocardial T1 measurements across centers. Critical relevance statement This review identifies technical drivers of T1 variability and proposes a standardization framework, enabling clinicians to establish accurate local reference ranges and improve diagnostic comparability across diverse platforms in clinical radiology practice.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Myocardial T1 Mapping at 3 T: A Comparison of MOLLI and ShMOLLI across Healthy Volunteers and Various Cardiovascular Pathologies.Radiology · 2026
- Native myocardial T1 reference values in a tunisian cohort using MOLLI and SMART1Map : List of Authors.Scientific reports · 2026
- Advancements in T1 Mapping for Cardiac MRI: Comprehensive Review of Techniques, Clinical Applications, Artificial Intelligence Integration, and Future Perspectives.Current cardiology reviews · 2026
- Cardiovascular magnetic resonance derived myocardial strain: applications, acquisition techniques, analysis, and reporting.European heart journal. Cardiovascular Imaging · 2026
- Cardiovascular Magnetic Resonance derived Myocardial Strain: Applications, Acquisition Techniques, Analysis, and Reporting. A Scientific Statement of the Society for Cardiovascular Magnetic Resonance, Radiological Society of North America, and European Association of Cardiovascular Imaging of the ESC.Radiology · 2026
- Reference intervals for myocardial T1, T2, and extracellular volume in clinically normal dogs and cats at 3-Tesla magnetic resonance imaging: a single-center studyAmerican Journal of Veterinary Research · 2026