From the paper's conclusion- Replacing 3D gradient-echo with post-contrast 3D T1 turbo spin-echo brain MRI greatly improves the detection of gadolinium-enhancing multiple-sclerosis lesions, boosting diagnostic sensitivity and reader agreement and directly influencing treatment-escalation decisions in routine practice.
Abstract
OBJECTIVES: To compare the performance of 3D T1 turbo spin echo (3DT1TSE) and 3D T1 turbo field echo (3DT1TFE) MRI in detecting gadolinium-enhancing lesions in multiple sclerosis (MS). MATERIALS AND METHODS: We retrospectively analyzed 255 3-T MRIs from MS patients, each including post-contrast 3DT1TSE and 3DT1TFE sequences. Two blinded readers independently assessed enhancing lesions per sequence. A consensus review, incorporating longitudinal imaging and additional sequences, served as the reference standard. RESULTS: The consensus identified 70 enhancing lesions in 31 patients. All 70 were visible on 3DT1TSE, while 64 (91%) were detectable on 3DT1TFE. Reader sensitivity was higher for 3DT1TSE (84% and 90%) than 3DT1TFE (45% and 40%) (p < 0.01). Inter-reader agreement was excellent for 3DT1TSE (ICC = 0.90) and moderate for 3DT1TFE (intraclass correlation coefficient = 0.69). Although false positives were more common with 3DT1TSE, they were readily excluded during consensus reading. In six patients, enhancing lesions were detected only on 3DT1TSE, with treatment escalation in two. CONCLUSION: 3DT1TSE outperformed 3DT1TFE in sensitivity and reader agreement for enhancing lesion detection in MS. Incorporating 3DT1TSE into standard MRI protocols may improve disease activity assessment and clinical decision-making. CRITICAL RELEVANCE STATEMENT: Replacing 3D gradient-echo with post-contrast 3D T1 turbo spin-echo brain MRI greatly improves the detection of gadolinium-enhancing multiple-sclerosis lesions, boosting diagnostic sensitivity and reader agreement and directly influencing treatment-escalation decisions in routine practice. KEY POINTS: Detecting and enhancing MS lesions is limited by standard 3D T1 turbo field echo (3DT1TFE) MRI. 3D T1 turbo spin echo detects significantly more gadolinium-enhancing MS lesions than conventional 3DT1TFE. Greater lesion detection allows more precise activity assessment and optimal treatment management.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- An optimized MP2RAGE protocol for spinal cord imaging in multiple sclerosisAmerican Journal of Neuroradiology · 2026
- Expert Panel Consensus Guidelines of the German Society of Neuroradiology on the Use of Magnetic Resonance Imaging in the Diagnosis and Monitoring of Multiple SclerosisClinical Neuroradiology · 2026
- 3-Tesla double inversion recovery MRI for improved detection of cervical cord lesions in multiple sclerosis: a cross-sectional studyEgyptian Journal of Radiology and Nuclear Medicine · 2026
- T1 dark-rim lesion count and disease duration in subsequent secondary progressive multiple sclerosis: an exploratory matched case-control study.Multiple sclerosis and related disorders · 2026
- Assessment of Dissemination in Time in Multiple Sclerosis Using a Single 3D T2-FLAIR magnetic resonance imaging Radiomic SignaturemedRxiv · 2026
- ACCURACY OF COMPRESSED SENSING ACCELERATED 3D-FLAIR IN THE DIAGNOSTIC WORK-UP OF MULTIPLE SCLEROSIS AT 1.5 TmedRxiv · 2026