Real-time continuous assessment of fatigue from surface electromyography with deep learning for training load regulation in elite cyclists.
Rongxuan Zhai, Guoqiang Ma, Jun Qiu, Mingxin Gong, Wenxin Niu, Lejun Wang
Department of Sports Medicine, Sport and Health Research Center, Shanghai YangZhi Rehabilitation Hospital (Shanghai Sunshine Rehabilitation Center), Physical Education Department, Tongji University, Shanghai, 200092, China. · Shanghai Research Institute of Sports Science (Shanghai Anti-doping Agency), Shanghai, 200030, China.
Key points
From the paper's conclusion- The proposed CNN-Bi-LSTM-attention framework enables accurate, continuous fatigue estimation from raw sEMG during high-intensity cycling, offering a promising tool for real-time fatigue monitoring and training load regulation in all-out cycling sprint.
Abstract
BACKGROUND: Accurate assessment of exercise-induced muscle fatigue is essential for optimizing training loads and preventing overtraining in elite athletes. This study presents a deep learning framework for continuous fatigue estimation from raw surface electromyography (sEMG) signals during high-intensity cycling. METHODS: Fourteen elite track cyclists performed a 30-second all-out sprint on a cycle ergometer. Power output was recorded at 1 Hz to derive a continuous fatigue index (percentage decline from peak power). Simultaneously, sEMG signals were recorded at 1000 Hz from four lower-limb muscles. A sliding window approach (3-second windows, 0.25-second stride) was used to construct input samples. A deep learning model integrating convolutional neural networks (CNN), bidirectional long short-term memory (Bi-LSTM), and channel attention mechanisms was developed to predict the fatigue index directly from raw sEMG. Model performance was evaluated using leave-one-subject-out cross-validation with subject-specific fine-tuning, and compared against eight baseline models. Ablation studies were conducted to quantify each component's contribution. RESULTS: The proposed CNN-Bi-LSTM-attention model achieved a mean absolute error of 0.048 ± 0.019 and a Pearson correlation coefficient of 0.822 ± 0.123, and was the only model yielding a positive coefficient of determination (R² = 0.493 ± 0.249). Compared to baseline machine learning models, the proposed model achieved superior prediction accuracy. Furthermore, it reduced prediction errors by 35.1% relative to time-only regression. Ablation studies revealed that removing the CNN or Bi-LSTM modules caused marked performance degradation, whereas removing the attention mechanism minimally affected prediction accuracy but enhanced model interpretability. CONCLUSIONS: The proposed CNN-Bi-LSTM-attention framework enables accurate, continuous fatigue estimation from raw sEMG during high-intensity cycling, offering a promising tool for real-time fatigue monitoring and training load regulation in all-out cycling sprint.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A cascaded CNN-LSTM framework for quantifying respiratory motion from surface electromyographic signalsPhysics in Medicine and Biology · 2026
- Real-Time Physiological Fatigue Prediction for Human-Robot Collaborative Manufacturing Using Wearable Sensor Fusion and Hybrid Deep Learning: An In Silico Digital Twin Study.Sensors (Basel, Switzerland) · 2026
- Fusion of Nine-Channel sEMG and Dual-IMU Sensors for Knee-Angle Estimation Based on CatBoost Feature Selection and Neuron-Level Attention LSTMBiosensors · 2026
- Machine Learning Methods to Predict Unmeasured Muscle Activation in Upper Limb Reaching Task for Assessing Population-Level Cross-Subject Generalizability.Journal of biomechanical engineering · 2026
- Joint and multiplex recurrence network analysis of muscle coordination during fatigue progression using sEMG.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2026
- Real-Time Fatigue Monitoring Using sEMG and HRV Sensors for Industrial Operators Under Swing Conditions.Sensors (Basel, Switzerland) · 2026