Modelling complex sports adaptation with electrocardiography: analysis of standard ECG, heart rate variability and QRST integral changes in elite athletes.
Dóra Boroncsok, Máté Babity, Márk Zámodics, Anna Menyhárt-Hetényi, Gergely Tuboly, György Kozmann, Regina Benkő, Alexandra Fábián,
Heart and Vascular Center, Semmelweis University, Városmajor street 68, Budapest, 1122, Hungary. · Department of Electrical Engineering and Information Systems, University of Pannonia, Egyetem street 10, Veszprém, 8200, Hungary.
Key points
From the paper's conclusion- Our findings indicate that a 1-minute lead I ECG recording can detect electrical differences between athletes and non-athlete controls and may provide a practical framework for future longitudinal studies of athletic cardiac adaptation.
Abstract
BACKGROUND: Basic resting electrocardiographic changes caused by regular intense exercise are known characteristics of the athlete's heart. Through detailed analysis of short-term ECG recordings, our aim was to study electrocardiographic, heart rate variability, and ventricular heterogeneity changes of the athlete's heart as a function of factors influencing sports adaptation. METHODS: Analysis of 1-minute resting lead I ECG recordings was used to determine standard ECG parameters, time-domain indicators of heart rate variability, and mean and standard deviation of QRST integrals. Statistical analysis was performed in Python development environment. RESULTS: 500 healthy athletes (age: 19[16-24]y, male: 55%, training: 16.7 ± 6.5 h/w) were compared with 100 non-athlete controls (age: 21[17-23]y, male: 51%). Athletes had lower heart rate (68[61-78]vs.82[73-91]BPM, p < 0.001), increased p-wave amplitude (89[71-108]vs.80[62-96]µV, p < 0.001), PQ interval (152[140-168]vs.142[132-152]ms, p < 0.001), QRS width (90[82-100]vs.82[78-90]ms, p < 0.001), T-wave amplitude (257[198-311]vs.195[146-248]µV, p < 0.001), SDNN (64.7[47.2-87.2]vs.50.6[36.5-66.3]ms, p < 0.001), RMSSD (52.6[34.8-78.3]vs.36.4[26.8-52.6]ms, p < 0.001), pNN50 (31.1[12.7-50.9]vs.14.7[4.9-31.6]%, p < 0.001) and mean QRST integral (34.9[28.3-43.4]vs.26.1[19.7-33.9]mV*ms, p < 0.001) compared to controls. Mixed athletes had wider QRS compared to power athletes (94[90-102]vs.88[84-96]ms, p < 0.005). Male athletes had lower QTc, increased PQ interval, QRS width, T-wave amplitude, mean QRST integral, and its deviation. In the control group, females had higher resting heart rate and QTc duration, while AVNN and the relative deviation of QRST integral were lower. Many of the above parameters also showed weak correlation with age and weekly exercise hours. CONCLUSIONS: Our findings indicate that a 1-minute lead I ECG recording can detect electrical differences between athletes and non-athlete controls and may provide a practical framework for future longitudinal studies of athletic cardiac adaptation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The Athlete's ECG: Sport-Specific Patterns, Physiological Remodeling, and Clinical Interpretation.JACC. Advances · 2026
- Cardiovascular adaptation to training load in endurance athletes: a longitudinal studyEuropean Heart Journal · 2025
- Normative Values for QRS Duration in Athletes aged 12-35 years undergoing Pre-participation Exams.Heart rhythm · 2026
- Bradycardia in Athletes: Prevalence, Mechanisms, and RisksCirculation · 2025
- Biological maturation, muscular fitness and cardiovascular asymmetry in pediatric female athletes: associations with ECG conduction and inter-arm blood pressure differencesEuropean Heart Journal · 2026
- Distinct Patterns of Autonomic Modulation in Athletes and Recreational Exercise Practitioners: A Cross-Sectional StudyJournal of Vascular Diseases · 2026