AQbD Driven RP-HPLC method for estimating rizatriptan benzoate and meloxicam: integrating green and blue analytical approaches.
Ramreddy Godela, Tharun Kumar Manumole, Lakshmi Satya Sri Kovvuri, Neha Bobba
Department of Pharmaceutical Analysis, GITAM School of Pharmacy, GITAM Deemed to be University, Hyderabad, 502329, India. ramreddy.godela@gmail.com. · Department of Pharmaceutical Analysis, GITAM School of Pharmacy, GITAM Deemed to be University, Hyderabad, 502329, India.
Key points
From the paper's conclusion- The proposed method is simple, reliable, robust, and sustainable for the simultaneous analysis of Rizatriptan Benzoate and Meloxicam.
Abstract
AIM: The present study aimed to develop and validate a robust, stability-indicating RP-HPLC method for the simultaneous determination of Rizatriptan Benzoate and Meloxicam using an Analytical Quality by Design approach integrated with green analytical principles. METHODS: A central composite design is used to evaluate critical method variables, such as flow rate and the percentage of organic phase. Separation was achieved on a Shimpack C18 column (250 × 4.6 mm, 5 μm) using methanol and 0.1% formic acid (80:20, v/v) as the mobile phase at a flow rate of 1.0 mL/min, with a detection wavelength of 296 nm. The method was validated in accordance with ICH guidelines for system suitability, linearity, precision, accuracy, robustness, specificity, sensitivity, and forced degradation studies. Greenness was assessed using AGREE, MoGAPI, and an Analytical Eco-Scale. Blue applicability grade index implemented to evaluate the practicality of a method in routine analysis. RESULTS: The optimized method showed retention times of 1.89 min for Rizatriptan Benzoate and 7.97 min for Meloxicam with a resolution of 23.3. Linearity was observed over the 5-50 µg/mL range, with correlation coefficients of 0.999 for Rizatriptan Benzoate and Meloxicam. The percentage recovery values ranged from 100.35% to 100.71%, and the percentage RSD for precision ranged from 0.62% to 0.98%, confirming the accuracy and precision of the method. The method also showed good robustness and specificity. The LOD values for RZT and MLX were 0.07 µg/mL and 0.19 µg/mL, respectively, while the LOQ values were 0.20 µg/mL and 0. 50 µg/mL, respectively. Green evaluation scores from AGREE (0.70), MoGAPI (80), and Analytical Eco Scale (77) confirmed the method as eco-friendly. The BAGI score of 80 ensures the practicality for routine use. CONCLUSION: The proposed method is simple, reliable, robust, and sustainable for the simultaneous analysis of Rizatriptan Benzoate and Meloxicam.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- AQbD-Driven Green RP-HPLC Method Development and Validation for Simultaneous Quantification of Apremilast and Quercetin in Nanostructured Lipid Carriers.Drug development and industrial pharmacy · 2026
- Green chemistry integrated quality by design based RP-HPLC method for analysis of Itraconazole in pharmaceutical formulationsDiscover Green Chemistry · 2026
- Integrated Approach of Risk‐Based Quality by Design and Multicolored Sustainable Analytical Chemistry to Stability‐Indicating Chromatographic Method for Concurrent Analysis of Sitagliptin and GlimepirideSeparation Science Plus · 2025
- Development of HPTLC method for simultaneous estimation of Gatifloxacin and Flurbiprofen Sodium using 32 factorial design.Drug development and industrial pharmacy · 2026
- Development of eco-friendly and sustainable analytical methods for Ritonavir through white analytical chemistry and AQbD approachDiscover Chemistry. · 2026
- Green RP-HPLC method for estimation of trigonelline: AQbD based development, validation, and application to nanoformulationsBMC Chemistry · 2026