BMC chemistry

Green chiral HPLC method on a polysaccharide column under hydro-organic conditions for the determination of Levobupivacaine, Ropivacaine, and their enantiomeric impurities.

Nehal G Sedki, Ahmed S Fayed, Nahla N Salama, Maha A Hegazy

Postgraduate program in Pharmaceutical Analytical Chemistry, Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Kasr El-Aini Street, Cairo, ET-11562, Egypt. nehalsedki82@gmail.com. · Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Kasr El-Aini Street, Cairo, ET-11562, Egypt.

Key points

From the paper's conclusion
  • To our knowledge, the developed method is the first application of hydro-organic conditions on a polysaccharide column for these local anesthetics, offering a rapid, selective, and sustainable alternative to traditional modes used in chiral LC methods.

Abstract

A novel, rapid, green, and enantioselective HPLC method was developed and validated using a polysaccharide-based chiral column for the individual determination of Levobupivacaine and S (-) Ropivacaine together with their respective chiral impurities (R (+) Bupivacaine and R (+) Ropivacaine). The separation was optimized on a Chiralpak AD column under hydro-organic conditions using an isocratic mobile phase of isopropanol and water (85:15, v/v) at flow rate 0.5 mL/min, with UV detection at 220 nm. The method was validated according to ICH guidelines and assessed for environmental impact using NEMI, Analytical Eco-Scale, GAPI, and AGREE tools. Baseline separation of each enantiomer pair was achieved within 8 min. Good linearity (R2 > 0.999) was exhibited over 20-200 μg/mL for the S-enantiomers and 2 - 20 μg/mL for the R-enantiomers. Precision (RSD < 1.36%) and accuracy (recoveries 99.4-100.7%) were satisfactory. Detection and quantitation limits for the chiral impurities were < 0.7 μg/mL and < 2.1 μg/mL, respectively. Thermodynamic studies indicated an enthalpy-driven enantioseparation involving hydrogen bonding, π-π interactions, and steric hindrance. The greenness assessment confirmed a superior environmental profile compared to literature methods, with an Eco-Scale score of 92 and AGREE score of 0.70. To our knowledge, the developed method is the first application of hydro-organic conditions on a polysaccharide column for these local anesthetics, offering a rapid, selective, and sustainable alternative to traditional modes used in chiral LC methods. Its simplicity and robustness make it well suited for routine quality control applications.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers