Journal of biological engineering

Diagnostic accuracy of liquid biopsy-based qPCR, ddPCR, and NGS in colorectal cancer: a systematic review and meta-analysis.

Seung Won You, Su Lim Kang, Ji Yean Kwon, Sung Min Kim

Department of Medical Device and Healthcare, Dongguk University-Seoul, 26, Pil-dong 3-ga, Jung-gu, Seoul, 04620, Republic of Korea. · Department of Medical Device and Healthcare, Dongguk University-Seoul, 26, Pil-dong 3-ga, Jung-gu, Seoul, 04620, Republic of Korea. sungmin2009@gmail.com.

Meta-analysis

Key points

From the paper's conclusion
  • Subgroup observations suggest that plasma-based mutation analysis using NGS exhibits promising diagnostic accuracy for CRC. Overall, these findings indicate that molecular liquid biopsy may serve as a potential non-invasive adjunct to complement traditional screening strategies, though further validation is required to confirm its clinical utility.

Abstract

BACKGROUND: Detection of colorectal cancer (CRC) significantly improves survival, yet current screening methods face challenges regarding invasiveness and patient compliance. Liquid biopsy has emerged as a promising non-invasive alternative. This systematic review and meta-analysis aimed to evaluate the diagnostic accuracy of liquid biopsy-based molecular diagnostics for colorectal cancer. METHODS: We searched PubMed, Embase, and Cochrane Library for studies evaluating the diagnostic accuracy of molecular liquid biopsy for CRC. Using a bivariate random-effects model, we estimated pooled sensitivity, specificity, and the area under the receiver operating characteristic curve (AUC). Meta-regression and subgroup analyses were performed to identify key drivers of performance, focusing on diagnostic platforms, biomarker types, and specimen sources. RESULTS: A total of 43 studies were included in the final analysis. The pooled sensitivity and specificity for liquid biopsy techniques (qPCR, ddPCR, and NGS) were 75% (95% CI, 0.70-0.79) and 91% (95% CI, 0.89-0.92), respectively. The SROC analysis revealed an AUC of 0.9121 (95% CI, 0.864-0.904). In subgroup analyses, NGS demonstrated a higher diagnostic odds ratio of 80.51 (95% CI, 26.13-248.08) and an AUC of 0.937. Furthermore, mutation-based biomarkers showed a diagnostic odds ratio of 45.78 (95% CI, 17.79-117.8) with an AUC of 0.944, while plasma samples had a diagnostic odds ratio of 32.19 (95% CI, 21.02-49.29) and an AUC of 0.912, indicating relatively higher diagnostic accuracy. CONCLUSION: Subgroup observations suggest that plasma-based mutation analysis using NGS exhibits promising diagnostic accuracy for CRC. Overall, these findings indicate that molecular liquid biopsy may serve as a potential non-invasive adjunct to complement traditional screening strategies, though further validation is required to confirm its clinical utility. CLINICAL TRIAL NUMBER: Not applicable.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers