Journal of cardiothoracic surgery

Early post-operative central collapse of an Ascyrus Medical Dissection Stent (AMDS) after acute type A aortic dissection repair: case report of successful TEVAR salvage.

James Lockhart, Jim Iliopoulos, Mehtab Ahmad

Department of Vascular Surgery, Liverpool Hospital, SWSLHD, NSW, Liverpool, Australia. lockhartjames418@gmail.com. · Department of Vascular Surgery, Liverpool Hospital, SWSLHD, NSW, Liverpool, Australia.

Case report

Key points

From the paper's conclusion
  • This case emphasises careful anatomical selection, early post-operative CTA surveillance and timely consideration of supportive TEVAR when collapse is identified.

Abstract

BACKGROUND: The Ascyrus Medical Dissection Stent (AMDS) is an adjunctive hybrid prosthesis designed to support true lumen expansion following type A aortic dissection repair. While early series demonstrate favourable aortic remodelling in selected patients, emerging data suggest a risk of central stent collapse. CASE PRESENTATION: The authors present a case of early post-operative central collapse of an AMDS stent following emergency Type A aortic dissection repair. Subsequent successful rescue treatment with a thoracic aortic endograft demonstrated a successful endovascular salvage strategy in this patient. CONCLUSIONS: This case emphasises careful anatomical selection, early post-operative CTA surveillance and timely consideration of supportive TEVAR when collapse is identified.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers