Journal of cardiothoracic surgery

A structured pre-procedural risk mitigation strategy for ultra-high-risk TAVR in a nonagenarian with extreme aortic valve calcification: a case report using a balloon-expandable valve and proactive ECMO backup.

Lang Hong, Zhaohui Liu, Xuehong Zhang, Chang Yao, Siping Peng

Department of Cardiology, Pingxiang People's Hospital, No. 8 Wugongshan Avenue, Anyuan District, Pingxiang, 337000, Jiangxi, China. · Department of Cardiology, Pingxiang People's Hospital, No. 8 Wugongshan Avenue, Anyuan District, Pingxiang, 337000, Jiangxi, China. 340425112@qq.com.

Case report

Key points

From the paper's conclusion
  • This case demonstrates the feasibility of a structured, pre-procedural risk mitigation strategy for TAVR in an exceptionally high-risk patient. The approach enabled the management of intraprocedural circulatory collapse. In this setting, the balloon-expandable valve platform demonstrated procedural characteristics that were well suited for this complex anatomy.

Abstract

BACKGROUND: Transcatheter aortic valve replacement (TAVR) in nonagenarians with extensive aortic valve calcification is associated with a substantial risk of intraprocedural circulatory collapse. CASE PRESENTATION: This case report describes a structured pre-procedural risk mitigation strategy integrating a balloon-expandable valve system and a pre-emptive, "wet-prepared" extracorporeal membrane oxygenation (ECMO) backup. A 97-year-old man with severe symptomatic aortic stenosis (peak velocity = 4.76 m/s; aortic valve calcium volume = 1178 mm³) underwent transfemoral TAVR using a structured approach incorporating precision imaging, careful device selection using a domestic Chinese balloon-expandable valve system (Prizvalve® TAV23), proactive ECMO preparedness, and multidisciplinary team coordination. Immediately after valve deployment, the patient developed circulatory collapse (blood pressure = 40/20 mmHg). A predefined emergency protocol was promptly activated. Following chest compressions, vasopressor administration, and pacing optimization, spontaneous circulation was restored within minutes. Angiography confirmed stable valve positioning with satisfactory expansion. At 3-month follow-up, echocardiography demonstrated absence of paravalvular leakage and preserved left ventricular systolic function. CONCLUSIONS: This case demonstrates the feasibility of a structured, pre-procedural risk mitigation strategy for TAVR in an exceptionally high-risk patient. The approach enabled the management of intraprocedural circulatory collapse. In this setting, the balloon-expandable valve platform demonstrated procedural characteristics that were well suited for this complex anatomy.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

A structured pre-procedural risk mitigation strategy for ultra-high-risk TAVR in a nonagenarian with extreme aortic valve calcification: a case report using a balloon-expandable valve and proactive ECMO backup — Science Skim