Biomechanical comparison of lumbar rotational manipulations in two different positions using force measurement and finite element analysis.
Jiasi Shen, Xilin Gao, Hongen Zheng, Xinyi Zhang, Zhen Li, Yue Fan, Wei Zhang, Ping Wang
First Teaching Hospital of Tianjin University of Traditional Chinese Medicine, Tianjin, 300381, China. · Xinjiang Production and Construction Corps Hospital, Xinjiang, 830002, China. weizhanglb@163.com.
Key points
From the paper's conclusion- Lateral decubitus and sitting LRM produced distinct regional biomechanical patterns. Lateral decubitus manipulation was characterized by a higher-stress/lower-displacement profile predominantly involving the lower lumbar spine, whereas sitting manipulation showed a lower-stress/higher-displacement profile with greater involvement of the upper lumbar spine. These findings provide a quantitative biomechanical basis for further investigation of technique-specific loading characteristics, tissue safety, and individualized clinical application.
Abstract
PURPOSE: To investigate the biomechanical characteristics of lateral decubitus and sitting lumbar rotational manipulations (LRM) by combining experimental force measurements with finite element analysis (FEA), with a particular focus on regional stress and displacement distributions and areas of stress concentration that may have relevance for future clinical and safety studies. METHODS: Twenty healthy volunteers were randomly assigned to receive either lateral decubitus or sitting LRM. Practitioner-generated forces were recorded using instrumented gloves, and preliminary cluster analysis was performed to explore distinct operational patterns. The measured loading parameters were then used to define the loading conditions in a validated lumbar finite element model to compare stress and displacement distributions in the intervertebral discs and facet cartilage across the two techniques and five clusters. RESULTS: Preliminary cluster analysis identified two clusters for the lateral decubitus technique (shoulder-hip coordinated and hip-dominant) and three for the sitting technique (shoulder-waist coordinated, shoulder-dominant, and gentle-loading). No significant left-right differences in practitioner-generated forces were observed for the lateral decubitus technique (all P > 0.05). For the sitting technique, the force applied at the shoulder was lower on the left than on the right (62.56 ± 15.58 vs. 77.70 ± 7.72 N; t = -10.088, P < 0.001), whereas the force applied at the waist was higher on the left than on the right [32.80 (27.75-38.20) vs. 26.06 (22.66-33.54) N; Z = 2.129, P = 0.042]. FEA showed distinct mechanical patterns between the two techniques. Across the two lateral decubitus clusters, the maximum intervertebral disc stress ranged from 7.87 to 13.40 MPa and the maximum deformation from 7.22 to 12.31 mm, with the main mechanical effects concentrated at L3/4-L4/5. Across the three sitting clusters, the maximum disc stress ranged from 5.87 to 8.09 MPa and the maximum deformation from 11.68 to 16.44 mm, with greater displacement mainly involving L1/2-L2/3. A similar contrast was observed in the facet cartilage, with the lateral decubitus technique generally producing higher peak stress but lower deformation than the sitting technique. CONCLUSION: Lateral decubitus and sitting LRM produced distinct regional biomechanical patterns. Lateral decubitus manipulation was characterized by a higher-stress/lower-displacement profile predominantly involving the lower lumbar spine, whereas sitting manipulation showed a lower-stress/higher-displacement profile with greater involvement of the upper lumbar spine. These findings provide a quantitative biomechanical basis for further investigation of technique-specific loading characteristics, tissue safety, and individualized clinical application. CLINICAL TRIAL NUMBER: Not applicable.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Optimizing lumbar therapy: a biomechanical study of oblique pulling manipulation under different postures.BMC complementary medicine and therapies · 2026
- Biomechanical effects of traditional Chinese exercises on scoliosis: a combined finite element and surface electromyography analysis.Frontiers in bioengineering and biotechnology · 2026
- Static and dynamic biomechanical responses of the lumbar spine under different loads: A finite element study.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2026
- Biomechanical Assessment of a Novel Self-Ligating Orthodontic Bracket Using Finite Element Analysis: The LUMACA System.Dentistry journal · 2026
- Surgeon Ergonomics of Lateral Lumbar Interbody Fusion Across Four Patient Positions: A Proof-of-Concept Simulation Study Using Motion Capture and Electromyography.Global spine journal · 2026
- Intraoperative six-axis loads during direct anterior approach total hip arthroplasty using a leg positioner: quantitative patterns across manoeuvres.International orthopaedics · 2026