Evaluation of an NS1-Based ZIKV/DENV IgG ELISA approach for serological differentiation in a dengue-endemic setting
Micaella C. Dato, Pichamon Sittikul, Pimolpachr Sribu, Jittraporn Rattanamahaphoom, Pannamas Maneekan, Kulachart Jangpatarapongsa, Supawat Chatchen, Pornsawan Leaungwutiwong
Mahidol University
Key points
From the paper's conclusion- The combination of two simple ELISAs may be applied for ZIKV serosurveys and to monitor ZIKV infection during pregnancy to understand the epidemiology, pathogenesis, and complications of ZIKV in DENV-endemic areas.
Abstract
Abstract Zika virus (ZIKV) is a mosquito-borne flavivirus that has recently emerged as a global health threat. The emergence of ZIKV has increased the incidence of neonates born with microcephaly or other neurological syndromes. The majority of ZIKV infections are mild or asymptomatic; however, clinical diagnosis is inaccurate. Moreover, Dengue virus cross-reacts with Zika antibodies, which creates problems for the serological diagnosis of ZIKV infections. Zika serological assays are often performed dismally in dengue-endemic areas because of this phenomenon. In this study, we established a Zika/Dengue ELISA Test to improve the differential diagnosis between Zika and Dengue samples. Sixty Zika-positive samples and 120 controls (20 Primary Dengue samples, 80 Secondary Dengue samples, and 20 healthy serum samples were tested using a ZNS1 and DNS1 Indirect ELISA and a commercial IgG ELISA Kit. Different Zika antigens (EDIII, MR766 NS1 and SV0127 NS1) were tested and ROC curves were compared. Among the antigens tested, NS1 yielded the best diagnostic potential with an AUC range of 0.84–0.88, compared with an AUC of 0.77–0.82 for EDIII. The Zika/Dengue OD Ratio also exhibited the best sensitivity (Sn) and specificity (Sp) (58.3% and 79.2% respectively) among the other parameters tested (Sn = 26.7%–28.3% and Sp = 59.2%–79.3%). It also performed better than the commercial kit, which yielded Sn and Sp values of only 26.7% and 74.2%, respectively. The Zika/Dengue OD Ratio has diagnostic potential and better performance compared with commercial ELISA test kits for detecting Zika infections. The combination of two simple ELISAs may be applied for ZIKV serosurveys and to monitor ZIKV infection during pregnancy to understand the epidemiology, pathogenesis, and complications of ZIKV in DENV-endemic areas.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Applying a multiplex electrochemiluminescence NS1 assay to detect and differentiate Zika and dengue virus exposures in long-term community cohorts in Brazil and ThailandmedRxiv · 2026
- Strain-Dependent Cross-Neutralization of Closely Related Asian-Lineage Zika Viruses by Dengue-Immune Sera.Biomolecules · 2026
- B-218 Improved and customized dengue serodiagnostics through combined NS1/IgM testing and novel dual-cut-off IgG ELISAClinical Chemistry · 2026
- Circulating Zika and dengue IgA-NS1 marks early postnatal exposure without significant association with congenital Zika syndrome-related microcephaly.The Journal of infectious diseases · 2026
- Anti-ZIKV IgG Subclass Profiles and Anti-DENV IgG Are Associated With Neonatal Outcomes Following ZIKV Infection During Pregnancy.Microbiology and immunology · 2026
- Nonstructural Protein 1 (NS1)-based IgG FcγR competition Enzyme-Linked Immunosorbent Assays (ELISAs) for highly specific serological profiling of previous flavivirus exposuresmedRxiv · 2026