Malaria journal

Quality assessment of malaria microscopy in Ouagadougou laboratories, Burkina Faso: accuracy of thick and thin blood smears.

Patindoilba Marcel Sawadogo, Jean Axel T Kaboré, Mamoudou Cissé, Kiswendsida Thierry Guiguemdé, Hermann Tapsoba, P Christian Compaoré, Adama Zida

Department of Parasitology-Mycology, Yalgado Ouédraogo University Hospital, BP 7022, Ouaga 03, Burkina Faso. · International Institute of Science and Technology (IISTech), Ouagadougou, Burkina Faso. kaborejeanaxeltegwende@gmail.com.

Observational

Key points

From the paper's conclusion
  • Routine malaria microscopy performance in the participating laboratories was limited by false-positive readings, highlighting the need for strengthened quality assurance and continuous competency-based training.

Abstract

BACKGROUND: Malaria microscopy remains the reference method for parasite detection in many low-resource settings, but its accuracy depends on slide preparation, staining quality, and reader performance. OBJECTIVE: This study aimed to assess the accuracy of routine malaria microscopy in selected laboratories in Ouagadougou, Burkina Faso. METHODS: We conducted a cross-sectional study in four laboratories in Ouagadougou, Burkina Faso, and re-examined 1000 malaria blood smears initially read by 29 laboratory providers using independent expert microscopy. The slides examined were the same as those used for routine diagnosis to ensure no bias remains in the interpretation of the results.-Routine microscopy was performed using single reading, while expert microscopy was performed using double reading to comply with the WHO standard. RESULTS: Twenty-nine microscopy providers participated, of whom 79.3% (23/29) were biomedical technicians, 17.2% (5/29) trainees, and 3.4% (1/29) biologists. Routine microscopy classified 184/1000 slides (18.4%) as positive and 816/1000 (81.6%) as negative, whereas expert re-reading identified 115/1000 (11.5%) as positive and 885/1000 (88.5%) as negative. Overall concordance was 88.1% (95% CI 85.9-90.0%), with a sensitivity of 78.3% (95% CI 69.9-84.8%), specificity of 89.4% (95% CI 87.2-91.2%), positive predictive value of 48.9% (95% CI 41.8-56.1%), and negative predictive value of 96.9% (95% CI 95.5-97.9%). Inter-reader agreement between routine and expert classification was moderate (Cohen's kappa = 0.54). Inaccurate routine readings were significantly associated with lack of refresher training and shorter slide-reading time. CONCLUSION: Routine malaria microscopy performance in the participating laboratories was limited by false-positive readings, highlighting the need for strengthened quality assurance and continuous competency-based training.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Quality assessment of malaria microscopy in Ouagadougou laboratories, Burkina Faso: accuracy of thick and thin blood smears — Science Skim